Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Application of blind deconvolution based on the new weighted L1-norm regularization with alternating direction method of multipliers in light microscopy images

Full metadata record
DC Field Value Language
dc.contributor.authorKim, J.-Y.-
dc.contributor.authorKim, K.-
dc.contributor.authorLee, Y.-
dc.date.available2020-10-27T01:40:17Z-
dc.date.created2020-10-23-
dc.date.issued2020-10-
dc.identifier.issn1431-9276-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78734-
dc.description.abstractThis study aimed to develop and evaluate a blind-deconvolution framework using the alternating direction method of multipliers (ADMMs) incorporated with weighted L1-norm regularization for light microscopy (LM) images. A presimulation study was performed using the Siemens star phantom prior to conducting the actual experiments. Subsequently, the proposed algorithm and a total generalized variation-based (TGV-based) method were applied to cross-sectional images of a mouse molar captured at 40× and 400× on-microscope magnifications and the results compared, and the resulting images were compared. Both simulation and experimental results confirmed that the proposed deblurring algorithm effectively restored the LM images, as evidenced by the quantitative evaluation metrics. In conclusion, this study demonstrated that the proposed deblurring algorithm can efficiently improve the quality of LM images. © 2020 World Scientific Publishing Co. Pte Ltd. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherCambridge University Press-
dc.relation.isPartOfMicroscopy and Microanalysis-
dc.titleApplication of blind deconvolution based on the new weighted L1-norm regularization with alternating direction method of multipliers in light microscopy images-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000576859800009-
dc.identifier.doi10.1017/S143192762000183X-
dc.identifier.bibliographicCitationMicroscopy and Microanalysis, v.26, no.5, pp.929 - 937-
dc.identifier.scopusid2-s2.0-85092641816-
dc.citation.endPage937-
dc.citation.startPage929-
dc.citation.titleMicroscopy and Microanalysis-
dc.citation.volume26-
dc.citation.number5-
dc.contributor.affiliatedAuthorKim, J.-Y.-
dc.contributor.affiliatedAuthorLee, Y.-
dc.type.docTypeArticle-
dc.subject.keywordAuthoralternating direction method of multipliers (ADMMs)-
dc.subject.keywordAuthorblind deconvolution-
dc.subject.keywordAuthordeblurring algorithm-
dc.subject.keywordAuthorlight microscope image-
dc.subject.keywordAuthorquantitative evaluation of image quality-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles
보건과학대학 > 치위생학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Youn photo

Kim, Ji Youn
Health Science (Dept.of Dental Hygiene)
Read more

Altmetrics

Total Views & Downloads

BROWSE