Application of blind deconvolution based on the new weighted L1-norm regularization with alternating direction method of multipliers in light microscopy images
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, J.-Y. | - |
dc.contributor.author | Kim, K. | - |
dc.contributor.author | Lee, Y. | - |
dc.date.available | 2020-10-27T01:40:17Z | - |
dc.date.created | 2020-10-23 | - |
dc.date.issued | 2020-10 | - |
dc.identifier.issn | 1431-9276 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78734 | - |
dc.description.abstract | This study aimed to develop and evaluate a blind-deconvolution framework using the alternating direction method of multipliers (ADMMs) incorporated with weighted L1-norm regularization for light microscopy (LM) images. A presimulation study was performed using the Siemens star phantom prior to conducting the actual experiments. Subsequently, the proposed algorithm and a total generalized variation-based (TGV-based) method were applied to cross-sectional images of a mouse molar captured at 40× and 400× on-microscope magnifications and the results compared, and the resulting images were compared. Both simulation and experimental results confirmed that the proposed deblurring algorithm effectively restored the LM images, as evidenced by the quantitative evaluation metrics. In conclusion, this study demonstrated that the proposed deblurring algorithm can efficiently improve the quality of LM images. © 2020 World Scientific Publishing Co. Pte Ltd. All rights reserved. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Cambridge University Press | - |
dc.relation.isPartOf | Microscopy and Microanalysis | - |
dc.title | Application of blind deconvolution based on the new weighted L1-norm regularization with alternating direction method of multipliers in light microscopy images | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000576859800009 | - |
dc.identifier.doi | 10.1017/S143192762000183X | - |
dc.identifier.bibliographicCitation | Microscopy and Microanalysis, v.26, no.5, pp.929 - 937 | - |
dc.identifier.scopusid | 2-s2.0-85092641816 | - |
dc.citation.endPage | 937 | - |
dc.citation.startPage | 929 | - |
dc.citation.title | Microscopy and Microanalysis | - |
dc.citation.volume | 26 | - |
dc.citation.number | 5 | - |
dc.contributor.affiliatedAuthor | Kim, J.-Y. | - |
dc.contributor.affiliatedAuthor | Lee, Y. | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | alternating direction method of multipliers (ADMMs) | - |
dc.subject.keywordAuthor | blind deconvolution | - |
dc.subject.keywordAuthor | deblurring algorithm | - |
dc.subject.keywordAuthor | light microscope image | - |
dc.subject.keywordAuthor | quantitative evaluation of image quality | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.