Detailed Information

Cited 12 time in webofscience Cited 12 time in scopus
Metadata Downloads

Chemically robust succinimide-group-assisted irreversible bonding of poly(dimethylsiloxane)-thermoplastic microfluidic devices at room temperature

Authors
Sivakumar, R.Lee, N.Y.
Issue Date
Nov-2020
Publisher
ROYAL SOC CHEMISTRY
Citation
ANALYST, v.145, no.21, pp.6887 - 6894
Journal Title
ANALYST
Volume
145
Number
21
Start Page
6887
End Page
6894
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78906
DOI
10.1039/d0an01268h
ISSN
0003-2654
Abstract
This study investigates surface chemical modification using anhydride silane and amino silane reagents at room temperature (RT) to realize bonding between silicon-based PDMS and non-silicon thermoplastics. The anhydride silane shows vigorous activity against water, forming a terminal dicarboxylic acid in the plasma-activated elastomeric poly(dimethylsiloxane) (PDMS) surface, and it can readily react with amino-silane-modified thermoplastic surfaces, resulting in a permanent bond via the formation of a stable succinimide group without the requirement for high temperature or additional pressure to initiate the bonding. The modified surfaces of PDMS and thermoplastics were successfully characterized by water contact angle measurement, fluorescence measurement, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). The bond strength values of PDMS-thermoplastic assemblies, measured by the tensile test for PDMS-polystyrene (PS), PDMS-poly(methyl methacrylate) (PMMA), PDMS-polycarbonate (PC), and PDMS-poly(ethyl terephthalate) (PET) assemblies, were found to be approximately 519.5 ± 6, 259 ± 15, 476.6 ± 8, and 458.2 ± 27 kPa, respectively. Moreover, the bond strength was further examined by performing a burst test for PDMS-PMMA, PDMS-PS, PDMS-PC, and PDMS-PET microfluidic devices, which were found to have the maximum pressure values at approximately 344.73, 448.15, 413.68, and 379.21 kPa, respectively. Based on these results, the hybrid microfluidic devices can be used for high-pressure experiments such as blood plasma separation and continuous-flow polymerase chain reaction (CF-PCR). We have also performed the large area bonding of the PDMS-PC assembly (10 × 10 cm2), ensuring the high robustness and reliability of the proposed surface chemical bonding method.
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 바이오나노학과 > 1. Journal Articles
산업·환경대학원 > 산업환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Sivakumar, Rajamanickam photo

Sivakumar, Rajamanickam
Graduate School of Environment (Dept of Industrial and Environmental Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE