Abstract
Background and Objectives: We evaluated the effectiveness and safety of EZ-CloseTM compared to those of hand suture for trocar-site closure according to obesity. Methods: Fifty-four cases of laparoscopic colorectal surgery were enrolled. For the same patient, the right port site was closed using EZ-CloseTM and left port site was closed by hand suture among cases with port-site diameter ≥10 mm. Cases switched to use of a conventional fascial closure device or with closure time 120 s were considered failures. Closure time was analyzed according to body mass index (BMI) and abdominal wall thickness (AWT). Results: The mean closure time was significantly shorter with EZ-CloseTM than with hand suture (87.9 ± 21.0 vs. 128.0 ± 59.0 s, p < 0.001). The number of failure cases was significantly lower with EZ-CloseTM than with hand suture (7 vs. 27, p < 0.001). The closure time of EZ-CloseTM was significantly shorter than that of hand suture in patients with BMI ≥ 25 and < 27 kg/m2 (n = 15, 85.9 ± 19.8 vs. 135.6 ± 67.9 s, p < 0.014) and ≥ 27 kg/m2 (n = 13, 85.1 ± 18.4 vs. 150.2 ± 70.6 s, p < 0.010). With respect to AWT, the closure time of EZ-CloseTM was significantly shorter than that of hand suture in patients with AWT ≥ 20 and < 26 mm (n = 12, 81.1 ± 11.5 vs. 142.3 ± 83.7 s, p = 0.023) and ≥ 26 mm (n = 17, 85.6 ± 22.6 vs. 160.2 ± 55.5, p < 0.001). No infection and herniation were detected in both trocar sites during the follow-up period (median 20.4 months). Conclusion: EZ-CloseTM could provide time efficiency in trocar-site closure, especially in obese patients. © 2020 by JSLS, Journal of the Society of Laparoscopic & Robotic Surgeons.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
의과대학 > 의예과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Dong Hyuk photo

Lee, Dong Hyuk
College of Medicine (Premedical Course)
Read more

Altmetrics

Total Views & Downloads

BROWSE