Hysteretic response of tilt-up concrete precast walls with embedded steel plate connections
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yun, H.-D. | - |
dc.contributor.author | Kim, H.-R. | - |
dc.contributor.author | Choi, W.-C. | - |
dc.date.available | 2020-11-23T00:40:38Z | - |
dc.date.created | 2020-10-19 | - |
dc.date.issued | 2020-09 | - |
dc.identifier.issn | 2071-1050 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/79050 | - |
dc.description.abstract | Many connection systems are available that can transfer tension and shear loads from a precast concrete wall panel to a floor slab. However, due to the insufficient anchor depth in relatively thin precast concrete panels, it is difficult to attain adequate ductility and stiffness to ensure structural integrity. Based on the authors' previous research results, the supplementary reinforcement of embedded steel plates in precast concrete wall panels can enhance stiffness while maintaining allowable displacement and ductility. In this study, three full-size tilt-up precast concrete panels with embedded steel plates were fabricated. Lateral cyclic loads were applied to full support structures consisting of a precast concrete wall panel and a foundation. The test results were compared with the results predicted using existing code equations found in the American Concrete Institute 318-14 and the Prestressed Concrete Institute Handbooks. The test results confirm that the supplementary reinforcement of thin precast concrete wall panels can provide (i) the required strength based on current code equations, (ii) sufficient ductility, and (iii) the energy dissipation capacity to resist cyclic loading. © 2020 by the authors. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MDPI AG | - |
dc.relation.isPartOf | Sustainability (Switzerland) | - |
dc.title | Hysteretic response of tilt-up concrete precast walls with embedded steel plate connections | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000586730600001 | - |
dc.identifier.doi | 10.3390/SU12197907 | - |
dc.identifier.bibliographicCitation | Sustainability (Switzerland), v.12, no.19 | - |
dc.identifier.scopusid | 2-s2.0-85092364426 | - |
dc.citation.title | Sustainability (Switzerland) | - |
dc.citation.volume | 12 | - |
dc.citation.number | 19 | - |
dc.contributor.affiliatedAuthor | Choi, W.-C. | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | Cyclic test | - |
dc.subject.keywordAuthor | Precast concrete wall panel | - |
dc.subject.keywordAuthor | Shear connector | - |
dc.subject.keywordAuthor | Supplementary reinforcement | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | ssci | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.