Detailed Information

Cited 7 time in webofscience Cited 7 time in scopus
Metadata Downloads

Noise level and similarity analysis for computed tomographic thoracic image with fast non-local means denoising algorithm

Full metadata record
DC Field Value Language
dc.contributor.authorKim, B.-G.-
dc.contributor.authorLee, Y.-
dc.contributor.authorKang, S.-H.-
dc.contributor.authorPark, C.R.-
dc.contributor.authorJeong, H.-W.-
dc.date.available2020-11-26T00:40:26Z-
dc.date.created2020-11-06-
dc.date.issued2020-11-
dc.identifier.issn2076-3417-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/79077-
dc.description.abstractAlthough conventional denoising filters have been developed for noise reduction from digital images, these filters simultaneously cause blurring in the images. To address this problem, we proposed the fast non-local means (FNLM) denoising algorithm which would preserve the edge information of objects better than conventional denoising filters. In this study, we obtained thoracic computed tomography (CT) images from a male adult mesh (MASH) phantom modeled by computer and a five-year-old phantom to perform both the simulation study and the practical study. Subsequently, the FNLM denoising algorithm and conventional denoising filters, such as the Gaussian, median, and Wiener filters, were applied to the MASH phantom image adding Gaussian noise with a standard deviation of 0.002 and practical CT images. Finally, the results were compared quantitatively in terms of the coefficient of variation (COV), contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), and correlation coefficient (CC). The results showed that the FNLM denoising algorithm was more efficient than the conventional denoising filters. In conclusion, through the simulation study and the practical study, this study demonstrated the feasibility of the FNLM denoising algorithm for noise reduction from thoracic CT images. © 2020 by the authors. Licensee MDPI, Basel, Switzerland.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI AG-
dc.relation.isPartOfApplied Sciences (Switzerland)-
dc.titleNoise level and similarity analysis for computed tomographic thoracic image with fast non-local means denoising algorithm-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000588900300001-
dc.identifier.doi10.3390/app10217455-
dc.identifier.bibliographicCitationApplied Sciences (Switzerland), v.10, no.21, pp.1 - 14-
dc.identifier.scopusid2-s2.0-85094681938-
dc.citation.endPage14-
dc.citation.startPage1-
dc.citation.titleApplied Sciences (Switzerland)-
dc.citation.volume10-
dc.citation.number21-
dc.contributor.affiliatedAuthorKim, B.-G.-
dc.contributor.affiliatedAuthorLee, Y.-
dc.contributor.affiliatedAuthorKang, S.-H.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorComputed tomography thoracic image-
dc.subject.keywordAuthorDenoising algorithm-
dc.subject.keywordAuthorFast non-local means approach-
dc.subject.keywordAuthorMASH phantom-
dc.subject.keywordAuthorNoise analysis-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE