Detailed Information

Cited 4 time in webofscience Cited 4 time in scopus
Metadata Downloads

Quantitative evaluation of the image quality using the fast nonlocal means denoising approach in diffusion-weighted magnetic resonance imaging with high b-value

Authors
Park, JaeyoungKang, Chang-KiLee, Youngjin
Issue Date
Feb-2021
Publisher
KOREAN PHYSICAL SOC
Keywords
Diffusion-weighted imaging (DWI); Fast nonlocal means (FNLM) approach; Image noise reduction; Magnetic resonance imaging; Medical physics
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.78, no.3, pp.244 - 250
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
78
Number
3
Start Page
244
End Page
250
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/79979
DOI
10.1007/s40042-020-00028-4
ISSN
0374-4884
Abstract
Brain images acquired using the diffusion-weighted imaging (DWI) method indicate that the diagnostic efficiency of infarction improves and the noise increases as the b-value increases. In this study, we designed a fast nonlocal means (FNLM) noise reduction algorithm and evaluated its effectiveness for de-noising brain images with high b-values. The designed algorithm uses an approach that measures the similarity of local parts in an image, calculates weights based on the result, and uses the principle of reducing processing time using a simplification of the calculation. To demonstrate the effectiveness of the algorithm, we compared the qualities of the images obtained using FNLM with those obtained using previously developed algorithms with noise reduction performance and no-reference image-quality assessment parameters. The results of applying the FNLM noise reduction algorithm to DWI images obtained at high b-values indicated superior quantitative characteristics. In particular, the signal-to-noise ratio, coefficient of variation, and blind/referenceless image spatial quality evaluator (BRISQUE) results using the proposed FNLM algorithm were approximately 1.84, 1.44, and 1.21 times better than those of the noisy image, respectively. In conclusion, our results verified that the FNLM approach achieves higher noise reduction efficiency in diffusion-weighted magnetic resonance imaging. © 2020, The Korean Physical Society.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE