Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Utility of fast non-local means (FNLM) filter for detection of pulmonary nodules in chest CT for pediatric patient

Authors
Shim, JinaYoon, MyonggeunLee, Mi-JungLee, Youngjin
Issue Date
Jan-2021
Publisher
ELSEVIER SCI LTD
Keywords
Chest CT; Fast non-local means (FNLM); Image quality; Pulmonary nodules
Citation
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, v.81, pp.52 - 59
Journal Title
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
Volume
81
Start Page
52
End Page
59
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/80467
DOI
10.1016/j.ejmp.2020.11.038
ISSN
1120-1797
Abstract
Purpose: This study was aimed to evaluate the utility based on imaging quality of the fast non-local means (FNLM) filter in diagnosing lung nodules in pediatric chest computed tomography (CT). Methods: We retrospectively reviewed the chest CT reconstructed with both filtered back projection (FBP) and iterative reconstruction (IR) in pediatric patients with metastatic lung nodules. After applying FNLM filter with six h values (0.0001, 0.001, 0.01, 0.1, 1, and 10) to the FBP images, eight sets of images including FBP, IR, and FNLM were analyzed. The image quality of the lung nodules was evaluated objectively for coefficient of variation (COV), contrast to noise ratio (CNR), and point spread function (PSF), and subjectively for noise, sharpness, artifacts, and diagnostic acceptability. Results: The COV was lowest in IR images and decreased according to increasing h values and highest with FBP images (P < 0.001). The CNR was highest with IR images, increased according to increasing h values and lowest with FBP images (P < 0.001). The PSF was lower only in FNLM filter with h value of 0.0001 or 0.001 than in IR images (P < 0.001). In subjective analysis, only images of FNLM filter with h value of 0.0001 or 0.001 rarely showed unacceptable quality and had comparable results with IR images. There were less artifacts in FNLM images with h value of 0.0001 compared with IR images (p < 0.001). Conclusion: FNLM filter with h values of 0.0001 allows comparable image quality with less artifacts compared with IR in diagnosing metastatic lung nodules in pediatric chest CT. © 2020
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE