Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Protective effect of angulated aorta for saving coronary artery during endovascular repair for ascending aortic pseudoaneurysm

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Myeong Gun-
dc.contributor.authorKang, Woong Chol-
dc.contributor.authorOh, Pyung Chun-
dc.contributor.authorBin Jeon, Yang-
dc.contributor.authorLee, Ji Yeon-
dc.contributor.authorShin, Eak Kyun-
dc.date.available2020-02-28T01:41:47Z-
dc.date.created2020-02-07-
dc.date.issued2016-08-
dc.identifier.issn2072-1439-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/8054-
dc.description.abstractAscending aortic pseudoaneurysm is a rare complication after cardiothoracic surgery and the open surgical repair for this complication is challenging. We report on a patient who developed an ascending aortic pseudoaneurysm after aortic valve replacement (AVR), which was treated successfully with endovascular therapy. Our case showed that angulation of the ascending aorta is one of factors for consideration in application of endovascular therapy and endovascular therapy might be an option for management of ascending aortic pathology in patients with high surgical risk, particularly patients with a severely angulated proximal ascending aorta.-
dc.language영어-
dc.language.isoen-
dc.publisherPIONEER BIOSCIENCE PUBL CO-
dc.relation.isPartOfJOURNAL OF THORACIC DISEASE-
dc.subjectFALSE ANEURYSM-
dc.titleProtective effect of angulated aorta for saving coronary artery during endovascular repair for ascending aortic pseudoaneurysm-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000385023800004-
dc.identifier.doi10.21037/jtd.2016.05.62-
dc.identifier.bibliographicCitationJOURNAL OF THORACIC DISEASE, v.8, no.8, pp.E667 - E671-
dc.identifier.scopusid2-s2.0-84990197586-
dc.citation.endPageE671-
dc.citation.startPageE667-
dc.citation.titleJOURNAL OF THORACIC DISEASE-
dc.citation.volume8-
dc.citation.number8-
dc.contributor.affiliatedAuthorKim, Myeong Gun-
dc.contributor.affiliatedAuthorKang, Woong Chol-
dc.contributor.affiliatedAuthorOh, Pyung Chun-
dc.contributor.affiliatedAuthorBin Jeon, Yang-
dc.contributor.affiliatedAuthorLee, Ji Yeon-
dc.contributor.affiliatedAuthorShin, Eak Kyun-
dc.type.docTypeArticle-
dc.subject.keywordAuthorAngulation of ascending aorta-
dc.subject.keywordAuthorascending aortic pseudoaneurysm-
dc.subject.keywordAuthorendovascular therapy-
dc.subject.keywordPlusFALSE ANEURYSM-
dc.relation.journalResearchAreaRespiratory System-
dc.relation.journalWebOfScienceCategoryRespiratory System-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Yang Bin photo

Jeon, Yang Bin
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE