Detailed Information

Cited 10 time in webofscience Cited 11 time in scopus
Metadata Downloads

Contrast, visibility, and color balance between the microscope versus intracameral illumination in cataract surgery using a 3D visualization system

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Young Jae-
dc.contributor.authorKim, Yu Jeong-
dc.contributor.authorNam, Dong Heun-
dc.contributor.authorKim, Kwang Gi-
dc.contributor.authorKim, Seong-Woo-
dc.contributor.authorChung, Tae-Young-
dc.contributor.authorLee, Sung Jin-
dc.contributor.authorPark, Kyu-Hyung-
dc.date.available2021-04-22T00:35:07Z-
dc.date.created2021-04-02-
dc.date.issued2021-04-
dc.identifier.issn0301-4738-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/80825-
dc.description.abstractPurpose: To compare image resolution and depth between the microscope versus intracameral illumination images during 3D heads-up cataract surgery. Methods: We collected 25 consecutive patients who had cataract surgery using the 3D viewing system. Based on bright, contrast, visibility, and color balance, the digital images (RGB color and three monochromes) extracted at the same point of the procedures were compared between the two illuminations. Results: Contrast values of green and blue channels except for red channel and visibility values of all three channels were higher in the intracameral illumination images than in the microscope images (P < 0.001, t-test). Color balance values of both green/red and blue/red were higher in the intracameral illumination images than in the microscope images (P < 0.001, t-test). Conclusion: The digital images in the digitally assisted cataract surgery were enhanced by using the intracameral illumination. Considering the contrast and color balance in the 3D cataract surgery, the intracameral illumination may be better than the microscope illumination.-
dc.language영어-
dc.language.isoen-
dc.publisherWOLTERS KLUWER MEDKNOW PUBLICATIONS, WOLTERS KLUWER INDIA PVT LTD-
dc.relation.isPartOfIndian journal of ophthalmology-
dc.titleContrast, visibility, and color balance between the microscope versus intracameral illumination in cataract surgery using a 3D visualization system-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000634641100030-
dc.identifier.doi10.4103/ijo.IJO_1825_20-
dc.identifier.bibliographicCitationIndian journal of ophthalmology, v.69, no.4, pp.927 - 931-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85103143202-
dc.citation.endPage931-
dc.citation.startPage927-
dc.citation.titleIndian journal of ophthalmology-
dc.citation.volume69-
dc.citation.number4-
dc.contributor.affiliatedAuthorKim, Young Jae-
dc.contributor.affiliatedAuthorNam, Dong Heun-
dc.contributor.affiliatedAuthorKim, Kwang Gi-
dc.type.docTypeArticle-
dc.subject.keywordAuthor3D visualization-
dc.subject.keywordAuthorcataract surgery-
dc.subject.keywordAuthorimage analysis-
dc.subject.keywordAuthorintracameral illumination-
dc.subject.keywordAuthormicroscope-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusarticle-
dc.subject.keywordPluscataract extraction-
dc.subject.keywordPlusclinical article-
dc.subject.keywordPluscontrolled study-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusillumination-
dc.subject.keywordPlusimage analysis-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusmicroscope image-
dc.subject.keywordPlusvisibility-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kwang Gi photo

Kim, Kwang Gi
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE