Detailed Information

Cited 4 time in webofscience Cited 4 time in scopus
Metadata Downloads

Development of a low-cost six-axis alignment instrument for flexible 2D and 3D ultrasonic probes

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Jungsuk-
dc.contributor.authorKim, Kwang Soo-
dc.contributor.authorChoi, Hojong-
dc.date.accessioned2021-05-10T00:40:22Z-
dc.date.available2021-05-10T00:40:22Z-
dc.date.created2021-04-19-
dc.date.issued2021-03-
dc.identifier.issn0928-7329-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/80957-
dc.description.abstractBACKGROUND: The pulse-echo test is used to evaluate the performance of ultrasonic probes before manufacturing ultrasonic systems. However, commercial alignment instruments are very large and use complex programs with long operation times. OBJECTIVE: To develop a low-cost alignment instrument used in the pulse-echo test for evaluating the performance of various 2D and 3D ultrasonic probes. METHODS: The developed alignment instrument can be aligned with the X, Y, Z, azimuth, elevation, and tilt axes with manual structure to support mounting fixtures that hold 2D and 3D ultrasonic probes. Each axis has a manual lever and is designed to have no movement when fixed. In particular, tilt and azimuth directions are designed to move more than 5°left and right. RESULTS: The probe mounted in the X, Y, and Z axes can move at above 50 mm. The probe mounted in the azimuth, elevation, and tilt axes can move more than 5°in the left and right directions. The pulse-echo test using commercial ultrasonic probes showed maximum error rate of less than 5%. CONCLUSIONS: Our developed alignment instrument can reduce costs by eliminating the need for shortening inspection times for probe manufacturers. © 2021-The authors. Published by IOS Press.-
dc.language영어-
dc.language.isoen-
dc.publisherIOS PRESS-
dc.relation.isPartOfTechnology and Health Care-
dc.titleDevelopment of a low-cost six-axis alignment instrument for flexible 2D and 3D ultrasonic probes-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000637955200009-
dc.identifier.doi10.3233/THC-218008-
dc.identifier.bibliographicCitationTechnology and Health Care, v.29, no.S1, pp.S77 - S84-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85103884171-
dc.citation.endPageS84-
dc.citation.startPageS77-
dc.citation.titleTechnology and Health Care-
dc.citation.volume29-
dc.citation.numberS1-
dc.contributor.affiliatedAuthorKim, Jungsuk-
dc.contributor.affiliatedAuthorChoi, Hojong-
dc.type.docTypeConference Paper-
dc.subject.keywordAuthoralignment instruments-
dc.subject.keywordAuthorUltrasonic probes-
dc.subject.keywordAuthorultrasonic transducers-
dc.subject.keywordAuthorwater tank-
dc.relation.journalResearchAreaHealth Care Sciences & Services-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryHealth Care Sciences & Services-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hojong photo

Choi, Hojong
반도체대학 (반도체·전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE