Detailed Information

Cited 2 time in webofscience Cited 3 time in scopus
Metadata Downloads

Additional roles of diastolic parameters in the diagnosis of obstructive coronary artery disease

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Hyue Mee-
dc.contributor.authorKim, Hack-Lyoung-
dc.contributor.authorKim, Myung-A-
dc.contributor.authorOh, Sohee-
dc.contributor.authorKim, Mina-
dc.contributor.authorPark, Sang Min-
dc.contributor.authorYoon, Hyun Ju-
dc.contributor.authorByun, Young Sup-
dc.contributor.authorPark, Seong Mi-
dc.contributor.authorShin, Mi Seung-
dc.contributor.authorHong, Kyung-Soon-
dc.contributor.authorShim, Wan-Joo-
dc.date.accessioned2021-05-14T00:40:07Z-
dc.date.available2021-05-14T00:40:07Z-
dc.date.created2021-03-15-
dc.date.issued2021-03-
dc.identifier.issn0954-6928-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/81010-
dc.description.abstractBACKGROUND: A recent guideline emphasizes the role of four indicators, including annular e´ velocity, E/e´, left atrial (LA) size, and peak tricuspid regurgitation (TR) velocity, in the assessment of left ventricular (LV) diastolic dysfunction. This study was performed to determine the relationships among these four parameters and obstructive coronary artery disease (CAD). METHODS: The study data were obtained from a nation-wide registry, composed of 1307 patients (age, 60.4 ± 10.8 years; 964 women) with normal LV ejection fraction (LVEF) who underwent invasive coronary angiography in the suspicion of CAD. Septal e´, E/e´, LA dimension (LAd), and TR velocity were assessed by transthoracic echocardiography. RESULTS: Compared with patients without obstructive CAD, those with obstructive CAD showed changes in diastolic parameters indicating more progressed LV diastolic dysfunction in univariate analyses. In multiple logistic regression analysis, low septal e´ velocity (<7 cm/s) was identified as an independent risk factor associated with obstructive CAD (odd ratio, 1.91; 95% confidence interval, 1.08-3.36; P = 0.026). Receiver-operating characteristic curve analysis showed that septal e´ velocity had the most powerful value in the detection of obstructive CAD than the other three diastolic parameters (P < 0.01 for each comparison). Septal e´ velocity significantly increased diagnostic value of treadmill exercise test (TET) in the detection of obstructive CAD (P < 0.001 for integrated discrimination improvement index). CONCLUSIONS: Among the four diastolic parameters, septal e´ velocity had the most powerful relationship with obstructive CAD in stable patients with normal LVEF. The addition of septal e´ velocity could improve the diagnostic value of TET. Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.relation.isPartOfCORONARY ARTERY DISEASE-
dc.titleAdditional roles of diastolic parameters in the diagnosis of obstructive coronary artery disease-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000639296000008-
dc.identifier.doi10.1097/MCA.0000000000000970-
dc.identifier.bibliographicCitationCORONARY ARTERY DISEASE, v.32, no.2, pp.145 - 151-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85101896066-
dc.citation.endPage151-
dc.citation.startPage145-
dc.citation.titleCORONARY ARTERY DISEASE-
dc.citation.volume32-
dc.citation.number2-
dc.contributor.affiliatedAuthorShin, Mi Seung-
dc.type.docTypeArticle-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Mi Seung photo

Shin, Mi Seung
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE