The accuracy of a partially guided system using an in-office 3D-printed surgical guide for implant placement
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Jin-yong | - |
dc.contributor.author | Kim, Sung-beom | - |
dc.contributor.author | Ryu, Jaeyoung | - |
dc.date.accessioned | 2021-05-31T01:40:25Z | - |
dc.date.available | 2021-05-31T01:40:25Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2021-02 | - |
dc.identifier.issn | 1463-4201 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/81129 | - |
dc.description.abstract | Aim: To conduct an observational study evaluating the efficacy of a partially guided system for implant surgery. Materials and methods: The study included 48 implant placements in 24 patients. Following virtual implant planning with designated software, a surgical guide was fabricated using a 3D desktop printer. Each surgically placed implant was compared with its planned position in the software. The coronal and apical distance and angular errors of the implants were evaluated. The correlation between the errors and the variables (residual bone height, surgeon, implant placement site, guide support type, implant diameter) was analyzed using multiple regression analysis. Results: The coronal and apical mean distance errors were 1.28±0.85and 1.8 ±0.97mm, respectively. The mean angular error was 3.66 ± 3.37 degrees. The correlation coefficients (coronal: 0.285; apical: 0.308) indicated a significant linear correlation between the anterior and posterior implant placement positions (P<0.05). Conclusion: A partially guided system with in-office guide fabrication using a 3D desktop printer is a useful option for implant placement. Copyright 2021, Quintessenz Verlags-GmbH | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | QUINTESSENCE PUBLISHING CO INC | - |
dc.relation.isPartOf | International Journal of Computerized Dentistry | - |
dc.title | The accuracy of a partially guided system using an in-office 3D-printed surgical guide for implant placement | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000652185200004 | - |
dc.identifier.bibliographicCitation | International Journal of Computerized Dentistry, v.24, no.1, pp.19 - 27 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-85105056304 | - |
dc.citation.endPage | 27 | - |
dc.citation.startPage | 19 | - |
dc.citation.title | International Journal of Computerized Dentistry | - |
dc.citation.volume | 24 | - |
dc.citation.number | 1 | - |
dc.contributor.affiliatedAuthor | Cho, Jin-yong | - |
dc.contributor.affiliatedAuthor | Kim, Sung-beom | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | computer-guided surgery | - |
dc.subject.keywordAuthor | dental implants | - |
dc.subject.keywordAuthor | printing | - |
dc.subject.keywordAuthor | surgical guide | - |
dc.subject.keywordAuthor | three-dimensional | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.