Detailed Information

Cited 1 time in webofscience Cited 3 time in scopus
Metadata Downloads

Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Chan Rok-
dc.contributor.authorKang, Seong-Hyeon-
dc.contributor.authorLee, Youngjin-
dc.date.accessioned2021-07-04T05:42:06Z-
dc.date.available2021-07-04T05:42:06Z-
dc.date.created2021-01-08-
dc.date.issued2021-06-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/81537-
dc.description.abstractIn the nuclear medicine imaging, quality control (QC) process using quadrant bar phantom is fundamental aspect of evaluating the spatial resolution. In addition, QC process of gamma camera is performed by daily or weekly. Recently, Monte Carlo simulation using the Geant4 application for tomographic emission (GATE) is widely applied in the pre-clinical nuclear medicine field for modeling gamma cameras with pixelated cadmium telluride (CdTe) semiconductor detector. In this study, we modeled a pixelated CdTe semiconductor detector and quadrant bar phantom (0.5, 1.0, 1.5, and 2.0 mm bar thicknesses) using the GATE tool. Similarity analysis based on correlation coefficients and peak signal-to-noise ratios was performed to compare image qualities for various source to collimator distances (0, 2, 4, 6, and 8 cm) and collimator lengths (0.2, 0.4, 0.6, 0.8, and 1.0 cm). To this end, we selected reference images based on collimator length and source to collimator distance settings. The results demonstrate that as the collimator length increases and the source to collimator distance decreases, the similarity to reference images improves. Therefore, our simulation results represent valuable information for the modeling of CdTe-based semiconductor gamma imaging systems and QC phantoms in the field of nuclear medicine. © 2020-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN NUCLEAR SOC-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.titleSimilarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000653016800011-
dc.identifier.doi10.1016/j.net.2020.12.010-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, v.53, no.6, pp.1947 - 1954-
dc.identifier.kciidART002721183-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85098535016-
dc.citation.endPage1954-
dc.citation.startPage1947-
dc.citation.titleNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.volume53-
dc.citation.number6-
dc.contributor.affiliatedAuthorKang, Seong-Hyeon-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorMonte Carlo simulation-
dc.subject.keywordAuthorNuclear medicine imaging system-
dc.subject.keywordAuthorPixelated cadmium telluride semiconductor detector-
dc.subject.keywordAuthorQuadrant bar phantom for quality control-
dc.subject.keywordAuthorSimilarity analysis-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE