Detailed Information

Cited 0 time in webofscience Cited 3 time in scopus
Metadata Downloads

Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)

Full metadata record
DC Field Value Language
dc.contributor.author강성윤-
dc.contributor.author이상민-
dc.contributor.author이상표-
dc.date.accessioned2021-07-17T04:40:22Z-
dc.date.available2021-07-17T04:40:22Z-
dc.date.created2021-07-06-
dc.date.issued2021-07-
dc.identifier.issn1738-3536-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/81691-
dc.description.abstractBackground: Fractional exhaled nitric oxide (FeNO) is a non-invasive marker for eosinophilic airway inflammation and a good predictor of response to corticosteroids. There is a need for a reliable and accurate measurement method, as FeNO measurements have been widely used in clinical practice. Our study aimed to compare two FeNO analyzers and derive a conversion equation for FeNO measurements in adults. Methods: We included 99 participants who had chief complaints of chronic cough and difficulty in breathing. The participants underwent concurrent FeNO measurement using NIOX VERO (Circassia AB) and NObreath (Bedfont). We compared the values of the two devices and analyzed their correlation and agreement. We then formulated an equation to convert FeNO values measured by NObreath into those obtained by NIOX VERO. Results: The mean age of the participants was 51.2±17.1 years, with a female predominance (58.6%). Approximately 60% of the participants had asthma. The FeNO level measured by NIOX VERO (median, 27; interquartile range [IQR], 15–45) was significantly lower than that measured by NObreath (median, 38; IQR, 22–58; p<0.001). There was a strong positive correlation between the two devices (r=0.779, p<0.001). Additionally, Bland-Altman plots and intraclass correlation coefficient demonstrated a good agreement. Using linear regression, we derived the following conversion equation: natural log (Ln) (NObreath)=0.728×Ln (NIOX VERO)+1.244. Conclusion: The FeNO values of NIOX VERO and NObreath were in good agreement and had positive correlations. Our proposed conversion equation could help assess the accuracy of the two analyzers.-
dc.language영어-
dc.language.isoen-
dc.publisher대한결핵및호흡기학회-
dc.relation.isPartOfTuberculosis and Respiratory Diseases-
dc.titleMeasurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000668235900003-
dc.identifier.doi10.4046/trd.2020.0137-
dc.identifier.bibliographicCitationTuberculosis and Respiratory Diseases, v.84, no.3, pp.182 - 187-
dc.identifier.kciidART002734886-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85109432325-
dc.citation.endPage187-
dc.citation.startPage182-
dc.citation.titleTuberculosis and Respiratory Diseases-
dc.citation.volume84-
dc.citation.number3-
dc.contributor.affiliatedAuthor강성윤-
dc.contributor.affiliatedAuthor이상민-
dc.contributor.affiliatedAuthor이상표-
dc.subject.keywordAuthorExhalation-
dc.subject.keywordAuthorNitric Oxide-
dc.subject.keywordAuthorBiomarkers-
dc.subject.keywordAuthorRespiratory Disease-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sang Pyo photo

Lee, Sang Pyo
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE