Detailed Information

Cited 4 time in webofscience Cited 6 time in scopus
Metadata Downloads

Optimization of mask size for median-modified Wiener filter according to matrix size of computed tomography images

Full metadata record
DC Field Value Language
dc.contributor.authorJu, Sunguk-
dc.contributor.authorKang, Seong-Hyeon-
dc.contributor.authorLee, Youngjin-
dc.date.accessioned2021-07-22T02:40:17Z-
dc.date.available2021-07-22T02:40:17Z-
dc.date.created2021-07-12-
dc.date.issued2021-09-11-
dc.identifier.issn0168-9002-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/81726-
dc.description.abstractWe investigated the variation in the noise level and image restoration efficiency as a function of the mask size of the median-modified Wiener filter (MMWF) as applied to computed tomography (CT) images of various matrix sizes. We applied the MMWF with various mask sizes to simulated images of various sizes, which were acquired images using the Shepp–Logan​ phantom and a Male Adult meSH phantom, and we found that for both phantoms, the noise level reduced as the mask size increased. In addition, we calculated the optimized mask size for each matrix size in the case of image-similarity evaluation. Moreover, we conducted an experimental study using the CT image of a chest phantom to evaluate the noise-reduction efficiency of the MMWF with the application of the optimized mask size by calculating the coefficient of variation (COV), signal to noise ratio (SNR), and contrast to noise ratio (CNR). As a result, compared to images without MMWF applied, the COV, SNR, and CNR of image with MMWF were improved by 2.01, 1.02, and 1.60 times, respectively. In conclusion, our findings demonstrate the importance of mask-size optimization (for a given matrix size) in improving the MMWF efficiency. © 2021 Elsevier B.V.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER-
dc.relation.isPartOfNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.titleOptimization of mask size for median-modified Wiener filter according to matrix size of computed tomography images-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000672430400006-
dc.identifier.doi10.1016/j.nima.2021.165508-
dc.identifier.bibliographicCitationNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.1010-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85109139247-
dc.citation.titleNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.volume1010-
dc.contributor.affiliatedAuthorJu, Sunguk-
dc.contributor.affiliatedAuthorKang, Seong-Hyeon-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorComputed tomography-
dc.subject.keywordAuthorMale Adult meSH phantom (MASH)-
dc.subject.keywordAuthorMedian modified Wiener filter (MMWF)-
dc.subject.keywordAuthorQuantitatively image-quality evaluation-
dc.subject.keywordPlusEfficiency-
dc.subject.keywordPlusImage enhancement-
dc.subject.keywordPlusImage quality-
dc.subject.keywordPlusImage reconstruction-
dc.subject.keywordPlusMedian filters-
dc.subject.keywordPlusMesh generation-
dc.subject.keywordPlusPhantoms-
dc.subject.keywordPlusQuality control-
dc.subject.keywordPlusSignal to noise ratio-
dc.subject.keywordPlusCoefficients of variations-
dc.subject.keywordPlusComputed tomography images-
dc.subject.keywordPlusMale adult mesh phantom (MASH)-
dc.subject.keywordPlusMatrix size-
dc.subject.keywordPlusMedian modified wiener filter-
dc.subject.keywordPlusNoise levels-
dc.subject.keywordPlusPhantoms-
dc.subject.keywordPlusQuantitatively image-quality evaluation-
dc.subject.keywordPlusSignal to noise-
dc.subject.keywordPlusWiener filter-
dc.subject.keywordPlusComputerized tomography-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE