Performance evaluation of median-modified Wiener filter algorithm in high-resolution complementary metal-oxide-semiconductor radio-magnetic X-ray imaging system: An experimental study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Seungwan | - |
dc.contributor.author | Lee, Youngjin | - |
dc.date.accessioned | 2021-07-22T02:40:21Z | - |
dc.date.available | 2021-07-22T02:40:21Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2021-09-11 | - |
dc.identifier.issn | 0168-9002 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/81727 | - |
dc.description.abstract | Noise reduction is a fundamental early stage in X-ray image performance evaluation. In this study, the median-modified Wiener filter (MMWF) algorithm based on a nonlinear adaptive spatial filter is compared to two general noise-reduction techniques using median and Wiener filters to confirm an excellent denoising approach in X-ray images. To acquire images, a high-resolution complementary metal–oxide–semiconductor (CMOS) radio-magnetic X-ray imaging system (exposure conditions: 100, 400, and 700μA) and rat phantom were used. The performances of the denoising methods were evaluated in terms of contrast-to-noise ratio (CNR), coefficient of variation (COV), and no-reference image quality assessment using the Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE). The average results for CNR, COV, and BRISQUE in the acquired X-ray image using the MMWF algorithm were 1.08, 1.10, and 1.03 times higher than those of the noisy image, respectively. On average, the MMWF algorithm provided better image restoration than general noise-reduction techniques and was found to be most effective in relatively lower exposure conditions. © 2021 Elsevier B.V. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER | - |
dc.relation.isPartOf | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.title | Performance evaluation of median-modified Wiener filter algorithm in high-resolution complementary metal-oxide-semiconductor radio-magnetic X-ray imaging system: An experimental study | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000672430400007 | - |
dc.identifier.doi | 10.1016/j.nima.2021.165509 | - |
dc.identifier.bibliographicCitation | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.1010 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-85107404582 | - |
dc.citation.title | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.citation.volume | 1010 | - |
dc.contributor.affiliatedAuthor | Lee, Youngjin | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | CMOS X-ray detector | - |
dc.subject.keywordAuthor | Experimental study | - |
dc.subject.keywordAuthor | Median-modified Wiener filter (MMWF) algorithm | - |
dc.subject.keywordAuthor | Noise-reduction algorithm | - |
dc.subject.keywordAuthor | Quantitative evaluation of image quality | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.