Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Predictors of Favorable Angiographic Outcomes After Drug-Coated Balloon Use for de novo Small Vessel Coronary Disease (DCB-ONLY)

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Woong Chol-
dc.contributor.authorPark, Sang Min-
dc.contributor.authorJang, Albert Youngwoo-
dc.contributor.authorOh, Pyung Chun-
dc.contributor.authorShin, Eun-Seok-
dc.contributor.authorYu, Cheol Woong-
dc.contributor.authorOh, Seung-Jin-
dc.contributor.authorKim, Yong Hoon-
dc.contributor.authorWon, Hoyoun-
dc.contributor.authorLee, Sang-Rok-
dc.contributor.authorLee, Sang Yeub-
dc.contributor.authorHong, Young Joon-
dc.contributor.authorLee, Sung Yun-
dc.contributor.authorKim, Byung Ok-
dc.contributor.authorKim, Sang-Wook-
dc.date.accessioned2021-10-21T01:40:08Z-
dc.date.available2021-10-21T01:40:08Z-
dc.date.created2021-05-24-
dc.date.issued2021-11-
dc.identifier.issn0003-3197-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/82419-
dc.description.abstractWe evaluated the angiographic parameter and clinical outcomes of drug-coated balloon (DCB) to assess the optimal angiographic criteria in de novo small vessel disease (SVD). Patients (n = 424, mean age: 64.4 ± 11.2 years, men: 69.8%) at 20 sites in Korea were prospectively enrolled. The primary end point was late luminal loss (LLL) at 9-month follow-up angiography. Secondary end points included restenosis rates, target lesion failure (TLF), and DCB-related thrombosis during the 12-month follow-up period. We included 403 patients for analysis excluding 21 patients who required bailout stenting. Baseline mean reference vessel.diameter was 2.52 ± 0.39 mm and mean minimal luminal diameter (MLD) was 0.71 ± 0.40 mm. The mean MLD was 1.54 ± 0.37 mm after DCB. Late luminal loss was −0.01 ± 0.43 mm and restenosis was noted in 26 patients (12.2%). Minimal luminal diameter >1.6 mm and %diameter stenosis (DS) <45% after DCB was associated maintenance of MLD without LLL at 9-months. Multivariate analysis demonstrated that %DS at baseline and post-MLD was associated with the restenosis. During 12-month follow-up, TLF was 2.6% including 1 cardiac death, 1 myocardial infarction, and 10 ischemia-driven target lesion revascularizations. Drug-coated balloon showed a low restenosis and lower LLL despite high in-segment DS. Post-MLD and % DS may be helpful to get optimal results in de novo SVD after DCB. © The Author(s) 2021.-
dc.language영어-
dc.language.isoen-
dc.publisherSAGE PUBLICATIONS INC-
dc.relation.isPartOfANGIOLOGY-
dc.titlePredictors of Favorable Angiographic Outcomes After Drug-Coated Balloon Use for de novo Small Vessel Coronary Disease (DCB-ONLY)-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000651969900001-
dc.identifier.doi10.1177/00033197211015534-
dc.identifier.bibliographicCitationANGIOLOGY, v.72, no.10, pp.986 - 993-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85105867157-
dc.citation.endPage993-
dc.citation.startPage986-
dc.citation.titleANGIOLOGY-
dc.citation.volume72-
dc.citation.number10-
dc.contributor.affiliatedAuthorKang, Woong Chol-
dc.contributor.affiliatedAuthorJang, Albert Youngwoo-
dc.contributor.affiliatedAuthorOh, Pyung Chun-
dc.type.docTypeArticle in Press-
dc.subject.keywordAuthordrug-coated balloon-
dc.subject.keywordAuthorlate luminal loss-
dc.subject.keywordAuthorsmall vessel coronary disease-
dc.subject.keywordAuthortarget lesion failure-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Albert Youngwoo photo

Jang, Albert Youngwoo
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE