Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Comparison study of image quality at various radiation doses for CT venography using advanced modeled iterative reconstruction

Full metadata record
DC Field Value Language
dc.contributor.authorHwang, Jung Han-
dc.contributor.authorKang, Jin Mo-
dc.contributor.authorPark, So Hyun-
dc.contributor.authorPark, Suyoung-
dc.contributor.authorKim, Jeong Ho-
dc.contributor.authorChoi, Sang Tae-
dc.date.accessioned2021-11-05T13:40:07Z-
dc.date.available2021-11-05T13:40:07Z-
dc.date.created2021-09-13-
dc.date.issued2021-08-
dc.identifier.issn1932-6203-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/82603-
dc.description.abstractObjective We compared the image quality according to the radiation dose on computed tomography (CT) venography at 80 kVp using advanced modeled iterative reconstruction for deep vein thrombus and other specific clinical conditions considering standard-, low-, and ultralowdose CT. Methods In this retrospective study, 105 consecutive CT venography examinations were included using a third-generation dual-source scanner in the dual-source mode in tubes A (reference mAs, 210 mAs at 70%) and B (reference mAs, 90 mAs at 30%) at a fixed 80 kVp. Two radiologists independently reviewed each observation of standard- (100% radiation dose), low- (70%), and ultralow-dose (30%) CT. The objective quality of large veins and subjective image quality regarding lower-extremity veins and deep vein thrombus were compared between images according to the dose. In addition, the CT dose index volumes were displayed from the images. Results From the patients, 24 presented deep vein thrombus in 69 venous segments of CT examinations. Standard-dose CT provided the lowest image noise at the inferior vena cava and femoral vein compared with low- and ultralow-dose CT (p < 0.001). There were no differences regarding subjective image quality between the images of popliteal and calf veins at the three doses (e.g., 3.8 ± 0.7, right popliteal vein, p = 0.977). The image quality of the 69 deep vein thrombus segments showed equally slightly higher scores in standard- and low-dose CT (4.0 ± 0.2) than in ultralow-dose CT (3.9 ± 0.4). The CT dose index volumes were 4.4 ± 0.6, 3.1 ± 0.4, and 1.3 ± 0.2 mGy for standard-, low-, and ultralow-dose CT, respectively. Conclusions Low- and ultralow-dose CT venography at 80 kVp using an advanced model based iterative reconstruction algorithm allows to evaluate deep vein thrombus and perform follow-up examinations while showing an acceptable image quality and reducing the radiation dose. © 2021 Hwang et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.-
dc.language영어-
dc.language.isoen-
dc.publisherPublic Library of Science-
dc.relation.isPartOfPLoS ONE-
dc.titleComparison study of image quality at various radiation doses for CT venography using advanced modeled iterative reconstruction-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000761695800020-
dc.identifier.doi10.1371/journal.pone.0256564-
dc.identifier.bibliographicCitationPLoS ONE, v.16, no.8-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85114332103-
dc.citation.titlePLoS ONE-
dc.citation.volume16-
dc.citation.number8-
dc.contributor.affiliatedAuthorHwang, Jung Han-
dc.contributor.affiliatedAuthorKang, Jin Mo-
dc.contributor.affiliatedAuthorPark, So Hyun-
dc.contributor.affiliatedAuthorPark, Suyoung-
dc.contributor.affiliatedAuthorKim, Jeong Ho-
dc.contributor.affiliatedAuthorChoi, Sang Tae-
dc.type.docTypeArticle-
dc.subject.keywordPlusDEEP-VEIN THROMBOSIS-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY VENOGRAPHY-
dc.subject.keywordPlusABDOMINAL CT-
dc.subject.keywordPlusREDUCTION-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Jin Mo photo

Kang, Jin Mo
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE