Detailed Information

Cited 4 time in webofscience Cited 4 time in scopus
Metadata Downloads

Two-Year Safety and Efficacy of Biodegradable Polymer Drug-Eluting Stent Versus Second-Generation Durable Polymer Drug-Eluting Stent in Patients With Acute Myocardial Infarction: Data from the Korea Acute Myocardial Infarction Registry (KAMIR)

Full metadata record
DC Field Value Language
dc.contributor.authorHur, Seung-Ho-
dc.contributor.authorKim, In-Cheol-
dc.contributor.authorWon, Ki-Bum-
dc.contributor.authorCho, Yun-Kyeong-
dc.contributor.authorYoon, Hyuck-Jun-
dc.contributor.authorNam, Chang-Wook-
dc.contributor.authorKim, Kwon-Bae-
dc.contributor.authorKim, Min-Seok-
dc.contributor.authorPark, Jincheol-
dc.contributor.authorRha, Seung-Woon-
dc.contributor.authorChae, Shung-Chull-
dc.contributor.authorKim, Young-Jo-
dc.contributor.authorKim, Chong-Jin-
dc.contributor.authorCho, Myeong-Chan-
dc.contributor.authorJeong, Myung-Ho-
dc.contributor.authorAhn, Young-Keun-
dc.contributor.authorKim, Hyo-Soo-
dc.contributor.authorAhn, Tae-Hoon-
dc.contributor.authorSeung, Ki-Bae-
dc.contributor.authorJang, Yangsoo-
dc.contributor.authorYoon, Jung-Han-
dc.contributor.authorSeong, In-Whan-
dc.contributor.authorHong, Taek-Jong-
dc.contributor.authorBae, Jang-Ho-
dc.contributor.authorPark, Seung-Jung-
dc.date.available2020-02-28T01:46:23Z-
dc.date.created2020-02-06-
dc.date.issued2016-05-
dc.identifier.issn0160-9289-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/8328-
dc.description.abstractBackground: Despite improved long-term safety of biodegradable polymer (BP) drug-eluting stents (DES) compared to first-generation durable polymer (DP) DES, data on the safety and efficacy of BP-DES compared with second-generation (2G) DP-DES in patients with acute myocardial infarction (AMI) are limited. Hypothesis: To evaluate the safety and efficacy of BP-DES compared with 2G-DP-DES in the higher stent thrombosis (ST) risk setting of AMI. Methods: A total of 3359 AMI patients who received either BP-DES (n=261) or 2G-DP-DES (n=3098) were included from the Korea Acute Myocardial Infarction Registry (KAMIR). Differences in baseline clinical and angiographic characteristics were adjusted using a 1:5 propensity score matching analysis (n=261 for BP-DES and n=1305 for 2G-DP-DES). The primary outcome was the incidence of major adverse cardiac events (MACE) including all-cause death, recurrent myocardial infarction (re-MI), and target vessel revascularization (TVR). The rate of definite or probable ST was also investigated. Results: In adjusted analysis, there was no significant difference between the 2 groups in baseline clinical and angiographic characteristics; 2-year MACE (10.7% and 9.9% in the BP-DES group and 2G-DP-DES group, respectively, P =0.679); ST incidence (0.8% vs 0.9%, respectively, P =1.0), and rates of all-cause death, re-MI, and TVR. By multivariate analysis, old age, diabetes mellitus, renal dysfunction, and left ventricular dysfunction were the independent predictors of MACE after BP-DES or 2G-DP-DES implantation. Conclusions: BP-DES and 2G-DP-DES appear to have comparable 2-year safety and efficacy for the treatment of AMI. However, longer-term follow-up is needed.-
dc.language영어-
dc.language.isoen-
dc.publisherWILEY-BLACKWELL-
dc.relation.isPartOfCLINICAL CARDIOLOGY-
dc.subjectBARE-METAL STENTS-
dc.subjectPERCUTANEOUS CORONARY INTERVENTION-
dc.subjectRANDOMIZED CONTROLLED-TRIALS-
dc.subjectVASCULAR-RESPONSE-
dc.subjectTHROMBOSIS-
dc.subjectMETAANALYSIS-
dc.subjectDISEASE-
dc.subjectCYPHER-
dc.titleTwo-Year Safety and Efficacy of Biodegradable Polymer Drug-Eluting Stent Versus Second-Generation Durable Polymer Drug-Eluting Stent in Patients With Acute Myocardial Infarction: Data from the Korea Acute Myocardial Infarction Registry (KAMIR)-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000379922900005-
dc.identifier.doi10.1002/clc.22525-
dc.identifier.bibliographicCitationCLINICAL CARDIOLOGY, v.39, no.5, pp.276 - 284-
dc.identifier.scopusid2-s2.0-84963579228-
dc.citation.endPage284-
dc.citation.startPage276-
dc.citation.titleCLINICAL CARDIOLOGY-
dc.citation.volume39-
dc.citation.number5-
dc.contributor.affiliatedAuthorAhn, Tae-Hoon-
dc.type.docTypeArticle-
dc.subject.keywordPlusBARE-METAL STENTS-
dc.subject.keywordPlusPERCUTANEOUS CORONARY INTERVENTION-
dc.subject.keywordPlusRANDOMIZED CONTROLLED-TRIALS-
dc.subject.keywordPlusVASCULAR-RESPONSE-
dc.subject.keywordPlusTHROMBOSIS-
dc.subject.keywordPlusMETAANALYSIS-
dc.subject.keywordPlusDISEASE-
dc.subject.keywordPlusCYPHER-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE