dc.description.abstract | For diagnosis of secondary lymphedema, amplitude mode (A-mode) examination using a single ultrasound probe has been suggested as one of the possible diagnostic modalities due to its relatively low cost, ease of usage, and mobility. However, A-mode ultrasound waves with respect to time have lots of noise and are complicated to analyze and achieve well-correlated information related to change in volume of each layer of skin and subcutaneous tissues. Thus, the development of an adequate ultrasound calibration phantom is needed. For this, a fundamental study on proper phantom materials which show acoustic characteristics of skin and subcutaneous tissues is needed. In this research, the fabrication method for ultrasonic phantom using gelatin material is presented in a wide range of acoustic impedance and their acoustic characteristics and usability were discussed. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | ASME International | - |
dc.relation.isPartOf | Journal of Engineering and Science in Medical Diagnostics and Therapy | - |
dc.title | Manufacturing of a Gelatin Phantom With Lymphedema for Ultrasonic Imaging Measurement | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.doi | 10.1115/1.4052661 | - |
dc.identifier.bibliographicCitation | Journal of Engineering and Science in Medical Diagnostics and Therapy, v.4, no.4 | - |
dc.description.isOpenAccess | N | - |
dc.citation.title | Journal of Engineering and Science in Medical Diagnostics and Therapy | - |
dc.citation.volume | 4 | - |
dc.citation.number | 4 | - |
dc.contributor.affiliatedAuthor | Yoon, Ki-Cheol | - |
dc.contributor.affiliatedAuthor | Kim, Kwang Gi | - |
dc.description.journalRegisteredClass | other | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.