Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Won-Joon-
dc.contributor.authorLee, Su-Jung-
dc.contributor.authorMoon, Cheol-Hyun-
dc.date.accessioned2022-02-19T02:40:53Z-
dc.date.available2022-02-19T02:40:53Z-
dc.date.created2022-01-25-
dc.date.issued2022-01-
dc.identifier.issn2234-7518-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/83515-
dc.description.abstractObjective: Although, digital models have recently been used in orthodontic clinics, physical models are still needed for a multitude of reasons. The purpose of this study was to assess whether the printed models can replace the plaster models by evaluating their accuracy in reproducing intermaxillary relationships and by appraising the clinicians’ ability to measure the printed models. Methods: Twenty sets of patients’ plaster models with well-established occlusal relationships were selected. Models were scanned using an intraoral scanner (Trios 3, 3Shape Dental System) by a single operator. Printed models were made with ZMD-1000B light-curing resin using the stereolithography method 3-dimensional printer. Validity, reliability, and reproducibility were evaluated using measurements obtained by three operators. Results: In evaluation of validity, all items showed no significant differences between measurements taken from plaster and printed models. In evaluation for reliability, significant differences were found in the distance between the gingival zeniths of #23–#33 (DZL_3) for the plaster models and at #17–#43 (DZCM_1) for the printed models. In evaluation for reproducibility, the plaster models showed significant differences between operators at midline, and printed models showed significant differences at 7 measurements including #17–#47 (DZR_7). Conclusions: The validity and reliability of intermaxillary relationships as determined by the printed model were clinically acceptable, but the evaluation of reproducibility revealed significant inter-operator differences. To use printed models as substitutes for plaster models, additional studies on their accuracies in measuring intermaxillary relationship are required.-
dc.language영어-
dc.language.isoen-
dc.publisher대한치과교정학회-
dc.relation.isPartOf대한치과교정학회지-
dc.titleEvaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000752540100002-
dc.identifier.doi10.4041/kjod.2022.52.1.20-
dc.identifier.bibliographicCitation대한치과교정학회지, v.52, no.1, pp.20 - 28-
dc.identifier.kciidART002806338-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85124811126-
dc.citation.endPage28-
dc.citation.startPage20-
dc.citation.title대한치과교정학회지-
dc.citation.volume52-
dc.citation.number1-
dc.contributor.affiliatedAuthorChoi, Won-Joon-
dc.contributor.affiliatedAuthorLee, Su-Jung-
dc.contributor.affiliatedAuthorMoon, Cheol-Hyun-
dc.type.docTypeArticle-
dc.subject.keywordAuthorPrinted model-
dc.subject.keywordAuthorIntermaxillary relationship-
dc.subject.keywordAuthorInter-operator difference-
dc.subject.keywordPlusINTRAORAL SCANNER-
dc.subject.keywordPlusPROTOTYPE TECHNOLOGIES-
dc.subject.keywordPlusLINEAR MEASUREMENTS-
dc.subject.keywordPlusRELIABILITY-
dc.subject.keywordPlusPLASTER-
dc.subject.keywordPlusVALIDITY-
dc.subject.keywordPlusRESIN-
dc.relation.journalResearchAreaDentistry, Oral Surgery & Medicine-
dc.relation.journalWebOfScienceCategoryDentistry, Oral Surgery & Medicine-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Cheol Hyun photo

Moon, Cheol Hyun
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE