Detailed Information

Cited 13 time in webofscience Cited 13 time in scopus
Metadata Downloads

Phacoemulsification using a chisel-shaped illuminator: enhanced depth trench, one-shot crack, and phaco cut

Full metadata record
DC Field Value Language
dc.contributor.authorWi, Jaemin-
dc.contributor.authorSeo, Hyejin-
dc.contributor.authorLee, Jong Yeon-
dc.contributor.authorNam, Dong Heun-
dc.date.available2020-02-28T02:41:55Z-
dc.date.created2020-02-06-
dc.date.issued2016-05-
dc.identifier.issn1120-6721-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/8356-
dc.description.abstractPurpose: To evaluate the efficacy and outcomes of intracameral illuminator-assisted nucleofractis technique in cataract surgery. Methods: Since June 2012, this novel technique has been performed in all cataract cases by one surgeon (approximately 300 cases of various densities). Trenching continues until the posterior plate white reflex between an endonucleus and an epinucleus is identified (enhanced depth trench). After trenching, cracking is initiated with minimal separation force, and completion of cracking is confirmed by posterior capsule reflex (one-shot crack). With followability enhanced by an elliptical phaco mode, the divided nucleus is efficiently cut into small fragments by a chisel-shaped illuminator (phaco cut). Results: We have not experienced any capsular bag or zonular complications, and the effective phacoemulsification time seemed to be shorter than that with the conventional technique. Conclusions: This technique simplifies the complete division of the nucleus, which is the most challenging step in safe and efficient phacoemulsification.-
dc.language영어-
dc.language.isoen-
dc.publisherWICHTIG PUBLISHING-
dc.relation.isPartOfEUROPEAN JOURNAL OF OPHTHALMOLOGY-
dc.subjectCATARACT-SURGERY-
dc.subjectEYES-
dc.subjectENDOILLUMINATION-
dc.subjectPHOTOTOXICITY-
dc.subjectVITRECTOMY-
dc.titlePhacoemulsification using a chisel-shaped illuminator: enhanced depth trench, one-shot crack, and phaco cut-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000380812100029-
dc.identifier.doi10.5301/ejo.5000667-
dc.identifier.bibliographicCitationEUROPEAN JOURNAL OF OPHTHALMOLOGY, v.26, no.3, pp.279 - 280-
dc.identifier.scopusid2-s2.0-84971351110-
dc.citation.endPage280-
dc.citation.startPage279-
dc.citation.titleEUROPEAN JOURNAL OF OPHTHALMOLOGY-
dc.citation.volume26-
dc.citation.number3-
dc.contributor.affiliatedAuthorWi, Jaemin-
dc.contributor.affiliatedAuthorSeo, Hyejin-
dc.contributor.affiliatedAuthorLee, Jong Yeon-
dc.contributor.affiliatedAuthorNam, Dong Heun-
dc.type.docTypeEditorial Material-
dc.subject.keywordAuthorChisel-shaped illuminator-
dc.subject.keywordAuthorEnhanced depth trench-
dc.subject.keywordAuthorOne-shot crack-
dc.subject.keywordAuthorPhaco cut-
dc.subject.keywordPlusCATARACT-SURGERY-
dc.subject.keywordPlusEYES-
dc.subject.keywordPlusENDOILLUMINATION-
dc.subject.keywordPlusPHOTOTOXICITY-
dc.subject.keywordPlusVITRECTOMY-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Nam, Dong Heun photo

Nam, Dong Heun
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE