Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Hexagonal Stimulation Digital Controller Design and Verification for Wireless Subretinal Implant Device

Full metadata record
DC Field Value Language
dc.contributor.authorAbbasi, Wajahat-
dc.contributor.authorChoi, Hojong-
dc.contributor.authorKim, Jungsuk-
dc.date.accessioned2022-05-13T07:40:05Z-
dc.date.available2022-05-13T07:40:05Z-
dc.date.created2022-05-12-
dc.date.issued2022-04-
dc.identifier.issn1424-8220-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84280-
dc.description.abstractSignificant progress has been made in the field of micro/nano-retinal implant technologies. However, the high pixel range, power leakage, reliability, and lifespan of retinal implants are still questionable. Active implantable devices are safe, cost-effective, and reliable. Although a device that can meet basic safety requirements set by the Food and Drug Administration and the European Union is reliable for long-term use and provides control on current and voltage parameters, it will be expensive and cannot be commercially successful. This study proposes an economical, fully controllable, and configurable wireless communication system based on field-programmable gated arrays (FPGAs) that were designed with the ability to cope with the issues that arise in retinal implantation. This system incorporates hexagonal biphasic stimulation pulses generated by a digital controller that can be fully controlled using an external transmitter. The integration of two separate domain analog systems and a digital controller based on FPGAs is proposed in this study. The system was also implemented on a microchip and verified using in vitro results.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.relation.isPartOfSensors-
dc.titleHexagonal Stimulation Digital Controller Design and Verification for Wireless Subretinal Implant Device-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000786868300001-
dc.identifier.doi10.3390/s22082899-
dc.identifier.bibliographicCitationSensors, v.22, no.8-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85127966060-
dc.citation.titleSensors-
dc.citation.volume22-
dc.citation.number8-
dc.contributor.affiliatedAuthorAbbasi, Wajahat-
dc.contributor.affiliatedAuthorChoi, Hojong-
dc.contributor.affiliatedAuthorKim, Jungsuk-
dc.type.docTypeArticle-
dc.subject.keywordAuthorfield-programmable gated arrays-
dc.subject.keywordAuthordigital controller-
dc.subject.keywordAuthorwireless telemetry system-
dc.subject.keywordAuthorhexagonal stimulation-
dc.subject.keywordPlusRETINAL PROSTHESIS-
dc.subject.keywordPlusTELEMETRY-
dc.subject.keywordPlusARRAY-
dc.subject.keywordPlusCHIP-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hojong photo

Choi, Hojong
반도체대학 (반도체·전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE