Hexagonal Stimulation Digital Controller Design and Verification for Wireless Subretinal Implant Device
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Abbasi, Wajahat | - |
dc.contributor.author | Choi, Hojong | - |
dc.contributor.author | Kim, Jungsuk | - |
dc.date.accessioned | 2022-05-13T07:40:05Z | - |
dc.date.available | 2022-05-13T07:40:05Z | - |
dc.date.created | 2022-05-12 | - |
dc.date.issued | 2022-04 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84280 | - |
dc.description.abstract | Significant progress has been made in the field of micro/nano-retinal implant technologies. However, the high pixel range, power leakage, reliability, and lifespan of retinal implants are still questionable. Active implantable devices are safe, cost-effective, and reliable. Although a device that can meet basic safety requirements set by the Food and Drug Administration and the European Union is reliable for long-term use and provides control on current and voltage parameters, it will be expensive and cannot be commercially successful. This study proposes an economical, fully controllable, and configurable wireless communication system based on field-programmable gated arrays (FPGAs) that were designed with the ability to cope with the issues that arise in retinal implantation. This system incorporates hexagonal biphasic stimulation pulses generated by a digital controller that can be fully controlled using an external transmitter. The integration of two separate domain analog systems and a digital controller based on FPGAs is proposed in this study. The system was also implemented on a microchip and verified using in vitro results. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.relation.isPartOf | Sensors | - |
dc.title | Hexagonal Stimulation Digital Controller Design and Verification for Wireless Subretinal Implant Device | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000786868300001 | - |
dc.identifier.doi | 10.3390/s22082899 | - |
dc.identifier.bibliographicCitation | Sensors, v.22, no.8 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.scopusid | 2-s2.0-85127966060 | - |
dc.citation.title | Sensors | - |
dc.citation.volume | 22 | - |
dc.citation.number | 8 | - |
dc.contributor.affiliatedAuthor | Abbasi, Wajahat | - |
dc.contributor.affiliatedAuthor | Choi, Hojong | - |
dc.contributor.affiliatedAuthor | Kim, Jungsuk | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | field-programmable gated arrays | - |
dc.subject.keywordAuthor | digital controller | - |
dc.subject.keywordAuthor | wireless telemetry system | - |
dc.subject.keywordAuthor | hexagonal stimulation | - |
dc.subject.keywordPlus | RETINAL PROSTHESIS | - |
dc.subject.keywordPlus | TELEMETRY | - |
dc.subject.keywordPlus | ARRAY | - |
dc.subject.keywordPlus | CHIP | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.