Detailed Information

Cited 7 time in webofscience Cited 8 time in scopus
Metadata Downloads

Redundant Electromagnetic Control of an Endoscopic Magnetic Capsule Driven by Multiple Electromagnets Configuration

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Jayoung-
dc.contributor.authorLee, Han-Sol-
dc.contributor.authorHoang, Manh Cuong-
dc.contributor.authorJeong, Seonghwan-
dc.contributor.authorKim, Jae-Seoung-
dc.contributor.authorLee, Cheong-
dc.contributor.authorKang, Byungjeon-
dc.contributor.authorLee, Jonghee-
dc.contributor.authorSon, Young-Don-
dc.contributor.authorBang, Seungmin-
dc.contributor.authorChoi, Eunpyo-
dc.contributor.authorPark, Jong-Oh-
dc.contributor.authorKim, Chang Sei-
dc.date.accessioned2022-05-19T00:40:04Z-
dc.date.available2022-05-19T00:40:04Z-
dc.date.created2021-11-13-
dc.date.issued2022-11-
dc.identifier.issn0278-0046-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84354-
dc.description.abstractIn this paper, we present a novel stationary electromagnetic actuation system (EMS) and a redundant magnetic field control approach that can enhance the magnetic actuation ability for a capsule endoscope. The EMS configured with multiple electromagnets has an intrinsic redundant problem when computing input current to each coil from inverse formulation. Here, we propose a redundant electromagnetic field control scheme of utilizing this redundancy to increase magnetic force and reduce the peak input current that deteriorates the performance. It is based on the optimization of magnetic field encountering input current and null-space equations of a pseudo-inverse matrix. We validated the proposed methods in simulation and experiments through the prototyped EMS designed by considering actual human size and a magnetic capsule endoscope. The results show significant improvements in the magnetic field and lower input current compared to the conventional method as well as extended operating time through reduced heating effects. Especially, the in vitro in a gastric phantom and in vivo experiments in a live pig could prove the practical applicability of the developed method for a magnetic capsule endoscope toward upper stomach diagnosis in the clinical environment. IEEE-
dc.language영어-
dc.language.isoen-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.relation.isPartOfIEEE Transactions on Industrial Electronics-
dc.titleRedundant Electromagnetic Control of an Endoscopic Magnetic Capsule Driven by Multiple Electromagnets Configuration-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000808129100060-
dc.identifier.doi10.1109/TIE.2021.3120443-
dc.identifier.bibliographicCitationIEEE Transactions on Industrial Electronics, v.69, no.11, pp.11370 - 11382-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85118552133-
dc.citation.endPage11382-
dc.citation.startPage11370-
dc.citation.titleIEEE Transactions on Industrial Electronics-
dc.citation.volume69-
dc.citation.number11-
dc.contributor.affiliatedAuthorKim, Jae-Seoung-
dc.contributor.affiliatedAuthorSon, Young-Don-
dc.type.docTypeArticle-
dc.subject.keywordAuthorElectromagnetic actuator-
dc.subject.keywordAuthorElectromagnetics-
dc.subject.keywordAuthorElectromagnets-
dc.subject.keywordAuthorEndoscopes-
dc.subject.keywordAuthorendoscopic magnetic capsule-
dc.subject.keywordAuthorMagnetic cores-
dc.subject.keywordAuthorMagnetic fields-
dc.subject.keywordAuthorMagnetic flux-
dc.subject.keywordAuthormedical microrobot-
dc.subject.keywordAuthormultiple electromagnets configuration-
dc.subject.keywordAuthorRedundant electromagnetic control-
dc.subject.keywordAuthorTorque-
dc.subject.keywordPlusElectromagnetic field effects-
dc.subject.keywordPlusElectromagnetic fields-
dc.subject.keywordPlusElectromagnets-
dc.subject.keywordPlusInverse problems-
dc.subject.keywordPlusMagnetic actuators-
dc.subject.keywordPlusElectromagnetic actuators-
dc.subject.keywordPlusElectromagnetic control-
dc.subject.keywordPlusElectromagnetics-
dc.subject.keywordPlusEndoscopic magnetic capsule-
dc.subject.keywordPlusInput current-
dc.subject.keywordPlusMagnetic capsule-
dc.subject.keywordPlusMagnetic-field-
dc.subject.keywordPlusMedical micro robots-
dc.subject.keywordPlusMultiple electromagnet configuration-
dc.subject.keywordPlusRedundant electromagnetic control-
dc.subject.keywordPlusEndoscopy-
dc.relation.journalResearchAreaAutomation & Control Systems-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryAutomation & Control Systems-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Son, Young Don photo

Son, Young Don
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE