Detailed Information

Cited 16 time in webofscience Cited 17 time in scopus
Metadata Downloads

Simultaneous Acquisition of Ultrasound and Gamma Signals with a Single-Channel Readout

Full metadata record
DC Field Value Language
dc.contributor.authorUllah, Muhammad Nasir-
dc.contributor.authorPark, Yuseung-
dc.contributor.authorKim, Gyeong Beom-
dc.contributor.authorKim, Chanho-
dc.contributor.authorPark, Chansun-
dc.contributor.authorChoi, Hojong-
dc.contributor.authorYeom, Jung-Yeol-
dc.date.accessioned2022-06-20T07:40:41Z-
dc.date.available2022-06-20T07:40:41Z-
dc.date.created2022-06-20-
dc.date.issued2021-02-
dc.identifier.issn1424-8220-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84713-
dc.description.abstractWe propose an integrated front-end data acquisition circuit for a hybrid ultrasound (US)-gamma probe. The proposed circuit consists of three main parts: (1) a preamplifier for the gamma probe, (2) a preprocessing analog circuit for the US, and (3) a digitally controlled analog switch. By exploiting the long idle time of the US system, an analog switch can be used to acquire data of both systems using a single output channel simultaneously. On the nuclear medicine (NM) gamma probe side, energy resolutions of 18.4% and 17.5% were acquired with the standalone system and with the proposed switching circuit, respectively, when irradiated with a Co-57 radiation source. Similarly, signal-to-noise ratios of 14.89 and 13.12 dB were achieved when US echo signals were acquired with the standalone system and with the proposed switching circuit, respectively. Lastly, a combined US-gamma probe was used to scan a glass target and a sealed radiation source placed in a water tank. The results confirmed that, by using a hybrid US-gamma probe system, it is possible to distinguish between the two objects and acquire structural information (ultrasound) alongside molecular information (gamma radiation source).-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.relation.isPartOfSensors-
dc.titleSimultaneous Acquisition of Ultrasound and Gamma Signals with a Single-Channel Readout-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000624697200001-
dc.identifier.doi10.3390/s21041048-
dc.identifier.bibliographicCitationSensors, v.21, no.4, pp.1 - 12-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85100232652-
dc.citation.endPage12-
dc.citation.startPage1-
dc.citation.titleSensors-
dc.citation.volume21-
dc.citation.number4-
dc.contributor.affiliatedAuthorChoi, Hojong-
dc.type.docTypeArticle-
dc.subject.keywordAuthorgamma probe-
dc.subject.keywordAuthorultrasound probe-
dc.subject.keywordAuthorhybrid systems-
dc.subject.keywordAuthorsilicon photomultiplier (SiPM)-
dc.subject.keywordAuthornuclear medicine (NM)-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hojong photo

Choi, Hojong
반도체대학 (반도체·전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE