Detailed Information

Cited 17 time in webofscience Cited 19 time in scopus
Metadata Downloads

In-situ application of an ANN algorithm for optimized chilled and condenser water temperatures set-point during cooling operation

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Won Hee-
dc.contributor.authorYoon, Yeobeom-
dc.contributor.authorLee, Je Hyeon-
dc.contributor.authorSong, Kwan Woo-
dc.contributor.authorChae, Young Tae-
dc.contributor.authorLee, Kwang Ho-
dc.date.accessioned2022-06-20T08:40:07Z-
dc.date.available2022-06-20T08:40:07Z-
dc.date.created2022-06-20-
dc.date.issued2021-02-
dc.identifier.issn0378-7788-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84727-
dc.description.abstractIn this study, an artificial neural network (ANN) based real-time predictive control and optimization algorithm for a chiller based cooling system was developed and applied to an actual building to analyze its cooling energy saving effects through in-situ application and actual measurements. For this purpose, we set the cooling tower's condenser water outlet temperature and the chiller's chilled water outlet temperature as the system control variables. To evaluate the algorithm performance, we compared and analyzed the electric consumption and the COP when the chilled and condenser water temperatures were controlled conventionally and controlled based on the ANN. As a result, the ANN model's accuracy was high, with a Cv(RMSE) of 4.9%. In addition, the ANN based control algorithm's energy analysis showed that the average energy saving rate for the chiller was 24.7% and that the total average energy saving effect for the chiller and cooling towers was 7.4%. The results confirmed that the proposed MPC algorithm could contribute to improved HVAC energy efficiency in commercial buildings. (C) 2020 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE SA-
dc.relation.isPartOfENERGY AND BUILDINGS-
dc.titleIn-situ application of an ANN algorithm for optimized chilled and condenser water temperatures set-point during cooling operation-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000712412900007-
dc.identifier.doi10.1016/j.enbuild.2020.110666-
dc.identifier.bibliographicCitationENERGY AND BUILDINGS, v.233-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85098945435-
dc.citation.titleENERGY AND BUILDINGS-
dc.citation.volume233-
dc.contributor.affiliatedAuthorChae, Young Tae-
dc.type.docTypeArticle-
dc.subject.keywordAuthorArtificial neural network-
dc.subject.keywordAuthorModel predictive control-
dc.subject.keywordAuthorChilled water temperature-
dc.subject.keywordAuthorCondenser water temperature-
dc.subject.keywordAuthorCooling energy-
dc.subject.keywordAuthorCOP-
dc.subject.keywordPlusARTIFICIAL NEURAL-NETWORKS-
dc.subject.keywordPlusHVAC SYSTEMS-
dc.subject.keywordPlusPREDICTIVE CONTROL-
dc.subject.keywordPlusENERGY-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusMODEL-
dc.subject.keywordPlusLOAD-
dc.subject.keywordPlusMPC-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 건축학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chae, Young Tae photo

Chae, Young Tae
Engineering (Division of Architecture & Architectural Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE