Comparison of the Optimized Intraocular Lens Constants Calculated by Automated and Manifest Refraction for Korean
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 엄영섭 | - |
dc.contributor.author | 임동희 | - |
dc.contributor.author | 김동현 | - |
dc.contributor.author | 변용수 | - |
dc.contributor.author | 나경선 | - |
dc.contributor.author | 김성재 | - |
dc.contributor.author | 노창래 | - |
dc.contributor.author | 정소향 | - |
dc.contributor.author | 이지은 | - |
dc.contributor.author | 조경진 | - |
dc.contributor.author | 정태영 | - |
dc.contributor.author | 김은철 | - |
dc.contributor.author | 신영주 | - |
dc.contributor.author | 이상목 | - |
dc.contributor.author | 조양경 | - |
dc.contributor.author | 윤경철 | - |
dc.contributor.author | 유인천 | - |
dc.contributor.author | 고병이 | - |
dc.contributor.author | 김홍균 | - |
dc.contributor.author | 송종석 | - |
dc.contributor.author | 이도형 | - |
dc.date.accessioned | 2022-09-16T00:40:04Z | - |
dc.date.available | 2022-09-16T00:40:04Z | - |
dc.date.created | 2022-09-16 | - |
dc.date.issued | 2022-09 | - |
dc.identifier.issn | 0378-6471 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/85458 | - |
dc.description.abstract | 목적: 한국인을 대상으로 백내장수술 후 자동굴절검사와 현성굴절검사로부터 최적화된 인공수정체 상수를 도출하고, 굴절검사 방법에따라 최적화된 인공수정체 상수에 차이가 있는지 확인하고자 하였다. 대상과 방법: 후향적 다기관 코호트 연구를 통하여 수정체유화술 및 인공수정체 낭내삽입술을 시행받은 환자 4,103명 4,103안이 18개기관에서 등록되었다. 동일한 생체계측장비와 인공수정체를 사용한 표본에서 자동굴절검사 또는 현성굴절검사로부터 SRK/T, Holladay, Hoffer Q, Haigis 공식의 최적화된 인공수정체 상수를 계산하였다. 자동굴절검사값과 현성굴절검사값으로 최적화된 인공수정체 상수를 비교하였다. 결과: 4,103안 중 IOLMaster 500으로 생체계측을 시행한 경우(62.9%)가 가장 많았으며, 다음은 IOLMaster 700 (15.2%)이었다. 총33가지의 인공수정체가 사용되었으며, Tecnis ZCB00 (53.0%)가 가장 많았다. 대상자 수가 많은 경우 자동굴절검사와 현성굴절검사로부터 최적화된 인공수정체 상수에 유의한 차이가 없었지만, 대상자 수가 적은 경우 자동굴절검사값으로부터 최적화된 인공수정체상수는 현성굴절검사값으로부터 최적화된 인공수정체 상수보다 유의하게 작았다. 결론: 한국인을 대상으로 최적화된 인공수정체 상수가 도출되어 인공수정체 도수 계산에 사용할 수 있게 되었다. 하지만 작은 표본집단에서 자동굴절검사값으로 인공수정체 상수를 최적화하는 경우, 인공수정체 상수가 작게 계산되어 수술 후 굴절 오차가 발생할 수 있다. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한안과학회 | - |
dc.relation.isPartOf | 대한안과학회지 | - |
dc.title | Comparison of the Optimized Intraocular Lens Constants Calculated by Automated and Manifest Refraction for Korean | - |
dc.title.alternative | 한국인 대상 자동굴절검사와 현성굴절검사로 계산된 최적화 인공수정체 상수 비교 | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000888864600002 | - |
dc.identifier.doi | 10.3341/jkos.2022.63.9.747 | - |
dc.identifier.bibliographicCitation | 대한안과학회지, v.63, no.9, pp.747 - 753 | - |
dc.identifier.kciid | ART002876171 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-85139206941 | - |
dc.citation.endPage | 753 | - |
dc.citation.startPage | 747 | - |
dc.citation.title | 대한안과학회지 | - |
dc.citation.volume | 63 | - |
dc.citation.number | 9 | - |
dc.contributor.affiliatedAuthor | 김동현 | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | Autorefraction | - |
dc.subject.keywordAuthor | Constants | - |
dc.subject.keywordAuthor | Intraocular lens | - |
dc.subject.keywordAuthor | Manifest refraction | - |
dc.subject.keywordAuthor | Optimization | - |
dc.subject.keywordPlus | OPTICAL COHERENCE TOMOGRAPHY | - |
dc.subject.keywordPlus | CATARACT-SURGERY | - |
dc.subject.keywordPlus | POWER | - |
dc.subject.keywordPlus | PREDICTION | - |
dc.subject.keywordPlus | BIOMETRY | - |
dc.subject.keywordPlus | OUTCOMES | - |
dc.subject.keywordPlus | FORMULA | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.relation.journalResearchArea | Ophthalmology | - |
dc.relation.journalWebOfScienceCategory | Ophthalmology | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.