Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Endotracheal intubation in rabbits using a video laryngoscope with a modified bladeopen access

Authors
Kim, YujinJeon, Hee YeonYang, InsookKim, Ji HyunChung, Jae HeeJu, Ji-HyeonKim, GyeonghunPark, Jun WonOh, Seung YeonSeong, Je KyungOh, Seung HyunJoo, Young-Shin
Issue Date
Jul-2022
Publisher
SPRINGERNATURE
Keywords
Rabbits; Inhalation anesthesia; Endotracheal intubation; Video laryngoscopes; Modified blade; Modified stylet
Citation
LABORATORY ANIMAL RESEARCH, v.38, no.1, pp.247 - 255
Journal Title
LABORATORY ANIMAL RESEARCH
Volume
38
Number
1
Start Page
247
End Page
255
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/85524
DOI
10.1186/s42826-022-00130-7
ISSN
1738-6055
Abstract
Rabbits are being increasingly used as companion animals, and in research; thus, the need for proper veterinary care for rabbits has increased. Surgical access is more challenging in rabbits under inhalation anesthesia compared to other animals, such as dogs and cats. Rabbits have a very narrow and deep oral cavity, large incisors, and a large tongue. Moreover, their temporomandibular joint has limited mobility, making it more difficult to approach the larynx. Various methods have been proposed to overcome this difficulty. The video laryngoscope was introduced in 1999 and is useful when airway intubation is unsuccessful using a conventional laryngoscope. We postulated that a video laryngoscope with a modified size 1 Macintosh blade (McGrath MAC Video Laryngoscope, Medtronic, USA) would facilitate the intubation of New Zealand White rabbits. Sixteen specific-pathogen-free male New Zealand White rabbits weighing 3.45-4.70 kg were studied. All rabbits were intubated using the video laryngoscope. Typically, a 3.0 mm endotracheal tube was used for rabbits weighing < 4 kg, while a 3.5 mm tube was used in those weighing > 4 kg. During surgery, anesthesia was well maintained, and there were no major abnormalities in the animals' conditions. No rabbit developed breathing difficulties or anorexia after recovering from anesthesia. We established an intubation method using a video laryngoscope with a modified blade and stylet in the supine (ventrodorsal) position and successfully applied it in 16 rabbits. It is useful for training novices and for treating rabbits in veterinary hospitals with few staff members and animal research facilities where there are insufficient human resources.
Files in This Item
There are no files associated with this item.
Appears in
Collections
약학대학 > 약학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Seung Hyun photo

Oh, Seung Hyun
Pharmacy (Dept.of Pharmacy)
Read more

Altmetrics

Total Views & Downloads

BROWSE