Detailed Information

Cited 2 time in webofscience Cited 4 time in scopus
Metadata Downloads

Effect of Calcar Screw in Locking Compression Plate System for Osteoporotic Proximal Humerus Fracture: A Finite Element Analysis Study

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Jung-Soo-
dc.contributor.authorKim, Jong Hoon-
dc.contributor.authorKim, Kwang Gi-
dc.contributor.authorYoon, Yong-Cheol-
dc.date.accessioned2022-10-22T02:40:10Z-
dc.date.available2022-10-22T02:40:10Z-
dc.date.created2022-10-10-
dc.date.issued2022-09-
dc.identifier.issn2314-6141-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/85826-
dc.description.abstractThis study proposes a finite element analysis (FEA) model for complex fractures at the osteoporotic proximal humerus and investigates the relevance of using a calcar screw in surgical treatments using this model. Two types of three-dimensional (3D) fracture models of patients with osteoporotic humerus were constructed reflecting the mechanical properties of the osteoporotic humerus, such as the Young’s modulus and Poisson’s ratio, and two load conditions mimicking the clinical environment were applied for simulation. Using the 3D models and the conditions, the FEA software calculated the concentration and distribution of stresses developing in the humerus, locking compression plate (LCP), and screws. Then, we evaluated and predicted the fixed state of a LCP system depending on whether the maximum stress value exceeded tensile strength. When axial force was applied, insertion of the calcar screw led to significant reduction of stress applied on screws in the fracture model having a medial gap by approximately 61%, from 913.20 MPa to 351.84 MPa. Based on the results, it was clearly confirmed that using of calcar screws improved the stability of a three-part fractures and simultaneously reinforced medial support.-
dc.language영어-
dc.language.isoen-
dc.publisherHindawi Limited-
dc.relation.isPartOfBioMed Research International-
dc.titleEffect of Calcar Screw in Locking Compression Plate System for Osteoporotic Proximal Humerus Fracture: A Finite Element Analysis Study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000864467500009-
dc.identifier.doi10.1155/2022/1268774-
dc.identifier.bibliographicCitationBioMed Research International, v.2022-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85138624367-
dc.citation.titleBioMed Research International-
dc.citation.volume2022-
dc.contributor.affiliatedAuthorLee, Jung-Soo-
dc.contributor.affiliatedAuthorKim, Jong Hoon-
dc.contributor.affiliatedAuthorKim, Kwang Gi-
dc.contributor.affiliatedAuthorYoon, Yong-Cheol-
dc.type.docTypeArticle-
dc.subject.keywordPlusMEDIAL SUPPORT-
dc.subject.keywordPlusFIXATION-
dc.subject.keywordPlusSTRAIN-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaResearch & Experimental Medicine-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryMedicine, Research & Experimental-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kwang Gi photo

Kim, Kwang Gi
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE