Detailed Information

Cited 3 time in webofscience Cited 4 time in scopus
Metadata Downloads

Optimization of block-matching and 3D filtering (BM3D) algorithm in brain SPECT imaging using fan beam collimator: Phantom study

Full metadata record
DC Field Value Language
dc.contributor.authorDo, Yongho-
dc.contributor.authorCho, Youngkwon-
dc.contributor.authorKang, Seong-Hyeon-
dc.contributor.authorLee, Youngjin-
dc.date.accessioned2022-10-23T01:40:05Z-
dc.date.available2022-10-23T01:40:05Z-
dc.date.created2022-09-03-
dc.date.issued2022-09-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/85834-
dc.description.abstractThe purpose of this study is to model and optimize the block-matching and 3D filtering (BM3D) algorithm and to evaluate its applicability in brain single-photon emission computed tomography (SPECT) images using a fan beam collimator. For quantitative evaluation of the noise level, the coefficient of variation (COV) and contrast-to-noise ratio (CNR) were used, and finally, a no-reference-based evaluation parameter was used for optimization of the BM3D algorithm in the brain SPECT images. As a result, optimized results were derived when the sigma values of the BM3D algorithm were 0.15, 0.2, and 0.25 in brain SPECT images acquired for 5, 10, and 15 s, respectively. In addition, when the sigma value of the optimized BM3D algorithm was applied, superior results were obtained compared with conventional filtering methods. In particular, we confirmed that the COV and CNR of the images obtained using the BM3D algorithm were improved by 2.40 and 2.33 times, respectively, compared with the original image. In conclusion, the usefulness of the optimized BM3D algorithm in brain SPECT images using a fan beam collimator has been proven, and based on the results, it is expected that its application in various nuclear medicine examinations will be possible. © 2022 Korean Nuclear Society-
dc.language영어-
dc.language.isoen-
dc.publisherKorean Nuclear Society-
dc.relation.isPartOfNuclear Engineering and Technology-
dc.titleOptimization of block-matching and 3D filtering (BM3D) algorithm in brain SPECT imaging using fan beam collimator: Phantom study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000862947300006-
dc.identifier.doi10.1016/j.net.2022.04.008-
dc.identifier.bibliographicCitationNuclear Engineering and Technology, v.54, no.9, pp.3403 - 3414-
dc.identifier.kciidART002867069-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85129857859-
dc.citation.endPage3414-
dc.citation.startPage3403-
dc.citation.titleNuclear Engineering and Technology-
dc.citation.volume54-
dc.citation.number9-
dc.contributor.affiliatedAuthorKang, Seong-Hyeon-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorBlock-matching and 3D filtering (BM3D) algorithm-
dc.subject.keywordAuthorBrain single photon emission computed tomography (SPECT)-
dc.subject.keywordAuthorOptimization of noise reduction algorithm-
dc.subject.keywordAuthorQuantitative evaluation of image quality-
dc.subject.keywordPlusEMISSION COMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusGAMMA-CAMERA SYSTEM-
dc.subject.keywordPlusPERFORMANCE EVALUATION-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusRESOLUTION-
dc.subject.keywordPlusQUALITY-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE