Advance continuous monitoring of blood pressure and respiration rate using denoising auto encoder and LSTM
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Seung-Ho | - |
dc.contributor.author | Choi, Seong-Jae | - |
dc.contributor.author | Park, Kyoung-Su | - |
dc.date.accessioned | 2022-11-02T00:40:14Z | - |
dc.date.available | 2022-11-02T00:40:14Z | - |
dc.date.created | 2022-01-28 | - |
dc.date.issued | 2022-10 | - |
dc.identifier.issn | 0946-7076 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/85924 | - |
dc.description.abstract | The importance of monitoring vital signs is increasing with the increase in the number of elderly people and deaths from chronic diseases worldwide. Various studies have been conducted for vital sign monitoring, and it has been confirmed that the transmit time, gradient, and amplitude of pulse signals are highly correlated with blood pressure (BP) and respiration rate (RR). In this study, a single photoplethysmography (PPG) sensor-based wearable device is designed for the continuous monitoring of BP, RR, and heart rate (HR). The device is designed as an earphone type for fixedness and signal stability; it transmits data via an Arduino-based Bluetooth module for wireless use and supplies power via batteries. Because of the similar frequency range between pulse signals and walking signals, denoising is difficult to perform via frequency analysis, where the noise of the PPG signal is isolated via denoising long short-term memory (LSTM) auto encoder. The gradient element, HR, and envelope are extracted as features from the denoised PPG signal, and BP regression models and RR measurement algorithms are designed based on these features. Finally, the reference vital signs and signals measured by the device are compared to verify the accuracy of the device. Results show that the average errors for diastolic blood pressure (DBP), systolic blood pressure (SBP) and RR are 3.93%, 6.38%, and 8.95%, respectively. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER HEIDELBERG | - |
dc.relation.isPartOf | MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | - |
dc.title | Advance continuous monitoring of blood pressure and respiration rate using denoising auto encoder and LSTM | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000744749700001 | - |
dc.identifier.doi | 10.1007/s00542-022-05249-0 | - |
dc.identifier.bibliographicCitation | MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, v.28, no.10, pp.2181 - 2190 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-85123259754 | - |
dc.citation.endPage | 2190 | - |
dc.citation.startPage | 2181 | - |
dc.citation.title | MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | - |
dc.citation.volume | 28 | - |
dc.citation.number | 10 | - |
dc.contributor.affiliatedAuthor | Park, Seung-Ho | - |
dc.contributor.affiliatedAuthor | Choi, Seong-Jae | - |
dc.contributor.affiliatedAuthor | Park, Kyoung-Su | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | PULSE | - |
dc.subject.keywordPlus | PHOTOPLETHYSMOGRAPHY | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.