Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Imaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Jun Seong-
dc.contributor.authorPark, So Hyun-
dc.contributor.authorPark, Suyoung-
dc.contributor.authorHwang, Jung Han-
dc.contributor.authorKim, Jeong Ho-
dc.contributor.authorPak, Seong Yong-
dc.contributor.authorLee, Kihyun-
dc.contributor.authorSchmidt, B.-
dc.date.accessioned2022-11-09T00:40:11Z-
dc.date.available2022-11-09T00:40:11Z-
dc.date.created2022-11-09-
dc.date.issued2022-09-
dc.identifier.issn1738-2637-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/85984-
dc.description.abstractPeripheral arterial disease (PAD) is common in elderly patients. Lower-extremity CT angiography (LE-CTA) can be useful for detecting PAD and planning its treatment. PAD can also be accurately evaluated on reconstructed monoenergetic images (MEIs) from low kiloelectron volt (keV) to high keV images using dual-energy CT. Low keV images generally provide higher contrast than high keV images but also feature more severe image noise. The noise-reduced virtual MEI reconstruction algorithm, called the Mono+ technique, was recently introduced to overcome such image noise. Therefore, this pictorial review aimed to present the imaging findings of PAD on LE-CTA and compare low and high keV images with those subjected to the Mono+ technique. We found that, in many cases, the overall and segmental image qualities were better and metal artifacts and venous contamination were decreased in the high keV images. © 2022 The Korean Society of Radiology.-
dc.language한국어-
dc.language.isoko-
dc.publisherKorean Radiological Society-
dc.relation.isPartOfJournal of the Korean Society of Radiology-
dc.titleImaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm-
dc.title.alternative가상의 단일 에너지 영상 재구성 기법을 이용한 하지 단층촬영 혈관조영술에서 말초 동맥 질환 영상 소견-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.doi10.3348/jksr.2021.0191-
dc.identifier.bibliographicCitationJournal of the Korean Society of Radiology, v.83, no.5, pp.1032 - 1045-
dc.identifier.kciidART002880577-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85140980545-
dc.citation.endPage1045-
dc.citation.startPage1032-
dc.citation.titleJournal of the Korean Society of Radiology-
dc.citation.volume83-
dc.citation.number5-
dc.contributor.affiliatedAuthorKim, Jun Seong-
dc.contributor.affiliatedAuthorPark, So Hyun-
dc.contributor.affiliatedAuthorPark, Suyoung-
dc.contributor.affiliatedAuthorHwang, Jung Han-
dc.contributor.affiliatedAuthorKim, Jeong Ho-
dc.contributor.affiliatedAuthorLee, Kihyun-
dc.type.docTypeArticle-
dc.subject.keywordAuthorComputed Tomography-
dc.subject.keywordAuthorLower Extremity-
dc.subject.keywordAuthorPeripheral Arterial Disease-
dc.subject.keywordAuthorX-Ray-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hwang, Jung Han photo

Hwang, Jung Han
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE