Detailed Information

Cited 2 time in webofscience Cited 10 time in scopus
Metadata Downloads

Development and Validation of Embedded Device for Electrocardiogram Arrhythmia Empowered with Transfer Learning

Full metadata record
DC Field Value Language
dc.contributor.authorAsif, Rizwana Naz-
dc.contributor.authorAbbas, Sagheer-
dc.contributor.authorKhan, Muhammad Adnan-
dc.contributor.authorAtta-ur-Rahman, Kiran-
dc.contributor.authorSultan, Kiran-
dc.contributor.authorMahmud, Maqsood-
dc.contributor.authorMosavi, Amir-
dc.date.accessioned2022-12-02T04:40:06Z-
dc.date.available2022-12-02T04:40:06Z-
dc.date.created2022-12-02-
dc.date.issued2022-10-
dc.identifier.issn1687-5265-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/86192-
dc.description.abstractWith the emergence of the Internet of Things (IoT), investigation of different diseases in healthcare improved, and cloud computing helped to centralize the data and to access patient records throughout the world. In this way, the electrocardiogram (ECG) is used to diagnose heart diseases or abnormalities. The machine learning techniques have been used previously but are feature-based and not as accurate as transfer learning; the proposed development and validation of embedded device prove ECG arrhythmia by using the transfer learning (DVEEA-TL) model. This model is the combination of hardware, software, and two datasets that are augmented and fused and further finds the accuracy results in high proportion as compared to the previous work and research. In the proposed model, a new dataset is made by the combination of the Kaggle dataset and the other, which is made by taking the real-time healthy and unhealthy datasets, and later, the AlexNet transfer learning approach is applied to get a more accurate reading in terms of ECG signals. In this proposed research, the DVEEA-TL model diagnoses the heart abnormality in respect of accuracy during the training and validation stages as 99.9% and 99.8%, respectively, which is the best and more reliable approach as compared to the previous research in this field.-
dc.language영어-
dc.language.isoen-
dc.publisherHINDAWI LTD-
dc.relation.isPartOfCOMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE-
dc.titleDevelopment and Validation of Embedded Device for Electrocardiogram Arrhythmia Empowered with Transfer Learning-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000875775600001-
dc.identifier.doi10.1155/2022/5054641-
dc.identifier.bibliographicCitationCOMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, v.2022-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85140284334-
dc.citation.titleCOMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE-
dc.citation.volume2022-
dc.contributor.affiliatedAuthorKhan, Muhammad Adnan-
dc.type.docTypeArticle-
dc.subject.keywordPlusECG-
dc.subject.keywordPlusNETWORK-
dc.subject.keywordPlusSYSTEM-
dc.relation.journalResearchAreaMathematical & Computational Biology-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalWebOfScienceCategoryMathematical & Computational Biology-
dc.relation.journalWebOfScienceCategoryNeurosciences-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Khan, Muhammad Adnan photo

Khan, Muhammad Adnan
College of IT Convergence (Department of Software)
Read more

Altmetrics

Total Views & Downloads

BROWSE