Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

가습기살균제 피해신청자들의 노출등급 분류 및 폐질환 발생 영향요인 분석

Full metadata record
DC Field Value Language
dc.contributor.author민기홍-
dc.contributor.author신정현-
dc.contributor.author조은경-
dc.contributor.author정다영-
dc.contributor.author류지윤-
dc.contributor.author김동준-
dc.contributor.author배성호-
dc.contributor.author신지훈-
dc.contributor.author이슬아-
dc.contributor.author최윤형-
dc.contributor.author양원호-
dc.contributor.author우재민-
dc.date.accessioned2023-01-17T05:40:49Z-
dc.date.available2023-01-17T05:40:49Z-
dc.date.created2023-01-17-
dc.date.issued2022-12-
dc.identifier.issn1738-4087-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/86605-
dc.description.abstractBackground: Lung injuries due to exposure to humidifier disinfectants (HDs) were reported in 2011 in South Korea. As a result of the government’s epidemiological investigation and toxicity test study, it was found that HDs caused health damage such as lung disease. Objectives: The purpose of this study was to classify HD exposure ratings and analyze the affecting factors that could identify the relationship with lung disease. Methods: Exposure assessment for HDs was conducted using a questionnaire during face-to-face interviews with the applicants. Ratings of high exposure (Class 1) and low exposure (Class 2) were cross-tabulated with clinical ratings (acceptable and unacceptable). Logistic regression analysis was carried out by setting the clinical rating of lung disease as a dependent variable and the socio-demographic and exposure characteristics obtained through the questionnaire as independent variables. Results: The concentration in air of polyhexamethylene guanidine (PHMG) was 71.96±107.47 µg/m3, and the exposure concentration was 15.21±23.28 µg/m3. The exposure rating was overestimated with 97.1% of affected subjects having high exposure using margin of exposure (MOE), but only 9.9% matching the clinical class. In the overestimated group, it could be explained by the fact that the exposure time was long and the subjects had already recovered from damage symptoms. As a result of logistic regression analysis, ten variables were found to be significant inf luencing factors. Conclusions: A new exposure rating could be calculated based on the MOE, and factors affecting lung disease could be estimated through comparative evaluation with the clinical rating.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국환경보건학회-
dc.relation.isPartOf한국환경보건학회지-
dc.title가습기살균제 피해신청자들의 노출등급 분류 및 폐질환 발생 영향요인 분석-
dc.title.alternativeAffecting Factors of Lung Disease and Classification of Exposure Rating of Applicants for Injuries from Humidifier Disinfectants-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.doi10.5668/JEHS.2022.48.6.324-
dc.identifier.bibliographicCitation한국환경보건학회지, v.48, no.6, pp.324 - 360-
dc.identifier.kciidART002907352-
dc.description.isOpenAccessY-
dc.citation.endPage360-
dc.citation.startPage324-
dc.citation.title한국환경보건학회지-
dc.citation.volume48-
dc.citation.number6-
dc.contributor.affiliatedAuthor이슬아-
dc.contributor.affiliatedAuthor최윤형-
dc.subject.keywordAuthorHumidifier disinfectant-
dc.subject.keywordAuthorexposure rating-
dc.subject.keywordAuthormargin of exposure-
dc.subject.keywordAuthorlung disease-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의예과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Yoon Hyeong photo

Choi, Yoon Hyeong
College of Medicine (Premedical Course)
Read more

Altmetrics

Total Views & Downloads

BROWSE