Comparison of Jaw Mode and Field Width for Left-Breast Cancer Using TomoDirect Three-Dimensional Conformal Radiation Therapy: A Phantom Study

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Haneul-
dc.contributor.authorJung, Jaehong-
dc.contributor.authorJung, Hyunseo-
dc.contributor.authorJeong, Jibeom-
dc.contributor.authorLee, Dohwa-
dc.contributor.authorJeong, Hyun-Woo-
dc.contributor.authorLee, Youngjin-
dc.date.accessioned2023-01-19T01:41:49Z-
dc.date.available2023-01-19T01:41:49Z-
dc.date.created2023-01-18-
dc.date.issued2022-12-
dc.identifier.issn2227-9032-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/86688-
dc.description.abstractIt is very important to use effective parameters in the treatment plan of breast cancer patients in TomoDirect (TD)-three-dimensional conformal radiation therapy (TD-3DCRT). The objective of this study was to compare the radiation treatment plans to the parameters (jaw width and jaw mode) of TD-3DCRT for left-breast cancer. This study was conducted using the phantom, the jaw mode (fixed and dynamic) and field width (2.5 cm and 5.0 cm) were controlled to compare the TD-3DCRT treatment plans. There was small difference in the conformity index (CI) and homogeneity index (HI) values for target according to the jaw mode for each field width. As a result of observation in terms of dose, treatment time and unnecessary damage to surrounding normal organs could be minimized when dynamic jaw with a field width of 5.0 cm was used. In conclusion, we verified that the use of dynamic jaws and 5.0 cm field width was effective in left-breast cancer radiotherapy plan using TD-3DCRT.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.relation.isPartOfHEALTHCARE-
dc.titleComparison of Jaw Mode and Field Width for Left-Breast Cancer Using TomoDirect Three-Dimensional Conformal Radiation Therapy: A Phantom Study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000901203000001-
dc.identifier.doi10.3390/healthcare10122431-
dc.identifier.bibliographicCitationHEALTHCARE, v.10, no.12-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85144660317-
dc.citation.titleHEALTHCARE-
dc.citation.volume10-
dc.citation.number12-
dc.contributor.affiliatedAuthorKim, Haneul-
dc.contributor.affiliatedAuthorJung, Hyunseo-
dc.contributor.affiliatedAuthorJeong, Jibeom-
dc.contributor.affiliatedAuthorLee, Dohwa-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorbreast cancer-
dc.subject.keywordAuthorradiation therapy-
dc.subject.keywordAuthorTomoDirect (TD)-
dc.subject.keywordAuthorthree-dimensional conformal radiation therapy (3D-CRT)-
dc.subject.keywordAuthorjaw mode and field width-
dc.subject.keywordPlusHELICAL TOMOTHERAPY-
dc.subject.keywordPlusRADIOTHERAPY-
dc.subject.keywordPlusWOMEN-
dc.relation.journalResearchAreaHealth Care Sciences & Services-
dc.relation.journalWebOfScienceCategoryHealth Care Sciences & Services-
dc.relation.journalWebOfScienceCategoryHealth Policy & Services-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassssci-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE