Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Optimal Nozzle Position and Patient's Posture to Enhance Drug Delivery into the Peritoneum during Rotational Intraperitoneal Pressurized Aerosol Chemotherapy in a Swine Model

Full metadata record
DC Field Value Language
dc.contributor.authorHwang, Dong Won-
dc.contributor.authorLee, Eun Ji-
dc.contributor.authorChung, Joo Yeon-
dc.contributor.authorLee, Eun Joo-
dc.contributor.authorKim, Dayoung-
dc.contributor.authorOh, Soo Hyun-
dc.contributor.authorLee, Seungmee-
dc.contributor.authorYim, Ga Won-
dc.contributor.authorShim, Seung-Hyuk-
dc.contributor.authorLee, Sung Jong-
dc.contributor.authorLee, San-Hui-
dc.contributor.authorPark, Ji Won-
dc.contributor.authorChang, Suk-Joon-
dc.contributor.authorPak, Kyung Ah-
dc.contributor.authorPark, Soo Jin-
dc.contributor.authorKim, Hee Seung-
dc.date.accessioned2023-01-19T01:42:17Z-
dc.date.available2023-01-19T01:42:17Z-
dc.date.created2023-01-18-
dc.date.issued2022-11-
dc.identifier.issn2075-4426-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/86721-
dc.description.abstractEven though rotational intraperitoneal pressurized aerosol chemotherapy (RIPAC) has been developed to improve the distribution and penetration depth of anti-cancer agents by pressurized intraperitoneal aerosol chemotherapy (PIPAC), the optimal nozzle position and patient's posture have not been investigated. Thus, we used nine pigs weighing 50-60 kg, and sprayed 150 mL of 1% methylene blue as an aerosol through the nozzle, DreamPen (R) (Dreampac Corp., Wonju, Republic of Korea), with a flow rate of 0.6 ml/min under a pressure of 140 to 150 psi for RIPAC in six and three pigs with supine and Trendelenburg positions, respectively. When we evaluated its distribution and penetration depth, even distribution among 13 regions of the abdomen was observed in three pigs with Trendelenburg position regardless of the depth of the nozzle. Regarding penetration depth, the numbers of regions with maximal penetration depth were high in the 2 cm depth of the nozzle with supine position (n = 5) and the 4 cm depth with Trendelenburg position (n = 3). Conclusively, even distribution and maximal penetration of anti-cancer agents can be expected during RIPAC in the medium depth (4 cm) between the nozzle inlet and the visceral peritoneum located on the opposite side of it and the Trendelenburg position.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.relation.isPartOfJOURNAL OF PERSONALIZED MEDICINE-
dc.titleOptimal Nozzle Position and Patient's Posture to Enhance Drug Delivery into the Peritoneum during Rotational Intraperitoneal Pressurized Aerosol Chemotherapy in a Swine Model-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000895538600001-
dc.identifier.doi10.3390/jpm12111799-
dc.identifier.bibliographicCitationJOURNAL OF PERSONALIZED MEDICINE, v.12, no.11-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85149683114-
dc.citation.titleJOURNAL OF PERSONALIZED MEDICINE-
dc.citation.volume12-
dc.citation.number11-
dc.contributor.affiliatedAuthorOh, Soo Hyun-
dc.type.docTypeArticle-
dc.subject.keywordAuthorperitoneal metastasis-
dc.subject.keywordAuthorrotational intraperitoneal pressurized aerosol chemotherapy-
dc.subject.keywordAuthornozzle position-
dc.subject.keywordAuthorposture-
dc.subject.keywordAuthordistribution-
dc.subject.keywordAuthorpenetration-
dc.subject.keywordPlusDISTRIBUTION PATTERN-
dc.subject.keywordPlusOVARIAN-
dc.subject.keywordPlusCARCINOMATOSIS-
dc.subject.keywordPlusDOXORUBICIN-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusPIPAC-
dc.relation.journalResearchAreaHealth Care Sciences & Services-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryHealth Care Sciences & Services-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE