Absorbed dose and image quality according to the scan mode and shield position in pediatric brain computed tomography scans

Full metadata record
DC Field Value Language
dc.contributor.authorBae, Eunmi-
dc.contributor.authorCho, Youngkwon-
dc.contributor.authorKim, Sungchul-
dc.date.accessioned2023-04-16T02:40:15Z-
dc.date.available2023-04-16T02:40:15Z-
dc.date.created2023-02-14-
dc.date.issued2023-04-
dc.identifier.issn0144-8420-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/87471-
dc.description.abstractIn this study, computed tomography dose index (CTDIvol), dose-length product (DLP), organ dose and signal-to-noise ratio (SNR) were measured in pediatric brain helical and volumetric CT scans using a pediatric phantom (equivalent to a 10-year-old) and optically stimulated luminescence dosemeters (OSLD) as the scan protocol used in Hospital A. Volumetric scans showed lower CTDIvol, DLP and organ dose than helical scans, and the SNR showed similar results. The organ doses were lower in the phantoms protected with front, rear or front and rear shielding than in those without shielding. However, no statistically significant differences were found among the different shield locations. In pediatric brain CT scans, to reduce exposure dose and patient discomfort while maintaining image quality, a volumetric scan rather than a helical scan was preferred, and a good shielding effect was observed with front or rear shielding.-
dc.language영어-
dc.language.isoen-
dc.publisherOXFORD UNIV PRESS-
dc.relation.isPartOfRADIATION PROTECTION DOSIMETRY-
dc.titleAbsorbed dose and image quality according to the scan mode and shield position in pediatric brain computed tomography scans-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000913760800001-
dc.identifier.doi10.1093/rpd/ncad001-
dc.identifier.bibliographicCitationRADIATION PROTECTION DOSIMETRY, v.199, no.5, pp.385 - 390-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85152167996-
dc.citation.endPage390-
dc.citation.startPage385-
dc.citation.titleRADIATION PROTECTION DOSIMETRY-
dc.citation.volume199-
dc.citation.number5-
dc.contributor.affiliatedAuthorKim, Sungchul-
dc.type.docTypeArticle-
dc.subject.keywordPlusCHILDREN-
dc.subject.keywordPlusCHEST-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sung Chul photo

Kim, Sung Chul
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE