Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Reference Standard for Digital Infrared Thermography of the Surface Temperature of the Lower Limbs

Full metadata record
DC Field Value Language
dc.contributor.authorZhang, Ho Yeol-
dc.contributor.authorSon, Seong-
dc.contributor.authorYoo, Byung Rhae-
dc.contributor.authorYouk, Tae-Mi-
dc.date.accessioned2023-05-16T00:43:20Z-
dc.date.available2023-05-16T00:43:20Z-
dc.date.created2023-05-15-
dc.date.issued2023-03-
dc.identifier.issn2306-5354-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/87700-
dc.description.abstractDigital infrared thermographic imaging (DITI) is a supplementary diagnostic technique to visualize the surface temperature of the human body. However, there is currently no reference standard for the lower limbs for accurate diagnosis. In this study, we performed DITI on the lower limbs of 905 healthy Korean volunteers (411 males and 494 females aged between 20 and 69 years) to obtain reference standard data. Thermography was conducted on the front, back, lateral sides, and sole area, and 188 regions of interest (ROIs) were analyzed. Additionally, subgroup analysis was conducted according to the proximity of ROIs, sex, and age groups. The mean temperatures of ROIs ranged from 24.60 +/- 5.06 to 28.75 +/- 5.76 degrees C and the absolute value of the temperature difference between both sides reached up to 1.06 +/- 2.75 degrees C. According to subgroup analysis, the sole area had a significantly lower temperature than any other areas, men had higher temperatures than women, and the elderly had higher temperatures than the young adults except for the 20s age group (p < 0.001, respectively). This result could be used as a foundation for the establishment of a reference standard for DITI. Practical patient DITI can be accurately interpreted using these data, and it can serve as a basis for further scientific research.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.relation.isPartOfBIOENGINEERING-BASEL-
dc.titleReference Standard for Digital Infrared Thermography of the Surface Temperature of the Lower Limbs-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000953676600001-
dc.identifier.doi10.3390/bioengineering10030283-
dc.identifier.bibliographicCitationBIOENGINEERING-BASEL, v.10, no.3-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85152686594-
dc.citation.titleBIOENGINEERING-BASEL-
dc.citation.volume10-
dc.citation.number3-
dc.contributor.affiliatedAuthorSon, Seong-
dc.contributor.affiliatedAuthorYoo, Byung Rhae-
dc.type.docTypeArticle-
dc.subject.keywordAuthorinfrared rays-
dc.subject.keywordAuthorlower limb-
dc.subject.keywordAuthorreference standard-
dc.subject.keywordAuthorskin temperature-
dc.subject.keywordAuthorthermography-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Son, Seong photo

Son, Seong
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE