INFLUENCE OF ACTIVE WATER STREAM, IRRADIANCE, AMBIENT TEMPERATURE, AND WIND SPEED ON THE EFFICIENCY OF FRESNEL LENS BASED TWO STAGE PVT SYSTEM
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Singhy, Arvind | - |
dc.contributor.author | Thakur, Robin | - |
dc.contributor.author | Kumar, Raj | - |
dc.contributor.author | Kumar, Sushil | - |
dc.contributor.author | Kumar, Sanjeev | - |
dc.contributor.author | Kumar, Sushil | - |
dc.contributor.author | Thapa, Sashank | - |
dc.date.accessioned | 2023-07-11T06:42:14Z | - |
dc.date.available | 2023-07-11T06:42:14Z | - |
dc.date.created | 2023-07-11 | - |
dc.date.issued | 2022-01-01 | - |
dc.identifier.issn | 0354-9836 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/88445 | - |
dc.description.abstract | Influence of wind speed, mass-flow rate of water, irradiance, and ambient temperature on concentrated photovoltaic thermal module (PVT) equipped with linear Fresnel lens as primary optic element and convex lens as secondary optic element have been investigated in this study. Influence of these parameters on module performance in terms of thermal efficiency and electrical efficiency are also examined during investigation. The thermal efficiency and electrical efficiency without consideration of parameters was found to be 14.3% and 51.2%, respectively. With consideration of mentioned four parameters, the results reveal that electrical efficiency of 17.2% and thermal efficiency of 55.3% can be achieved for designed set-up. Thus, there is 20% and 8% increase in electrical efficiency and thermal efficiency, respectively. The electrical efficiency increases with increase in flluid-flow rate, wind speed, and irradiance. Electrical efficiency decreases with increase in ambient temperature. The thermal efficiency increases with increment in water mass-flow rate, irradiance, and ambient temperature. However, with increase in wind speed, the thermal efficiency decreases. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | VINCA INST NUCLEAR SCI | - |
dc.relation.isPartOf | THERMAL SCIENCE | - |
dc.title | INFLUENCE OF ACTIVE WATER STREAM, IRRADIANCE, AMBIENT TEMPERATURE, AND WIND SPEED ON THE EFFICIENCY OF FRESNEL LENS BASED TWO STAGE PVT SYSTEM | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000799173800035 | - |
dc.identifier.doi | 10.2298/TSCI200801193S | - |
dc.identifier.bibliographicCitation | THERMAL SCIENCE, v.26, no.2, pp.1139 - 1150 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.scopusid | 2-s2.0-85117579199 | - |
dc.citation.endPage | 1150 | - |
dc.citation.startPage | 1139 | - |
dc.citation.title | THERMAL SCIENCE | - |
dc.citation.volume | 26 | - |
dc.citation.number | 2 | - |
dc.contributor.affiliatedAuthor | Kumar, Raj | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | heat exchanger | - |
dc.subject.keywordAuthor | PVT | - |
dc.subject.keywordAuthor | Fresnel lens | - |
dc.subject.keywordAuthor | thermal efficiency | - |
dc.subject.keywordAuthor | electrical efficiency | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | SIMULATION | - |
dc.subject.keywordPlus | BUILDINGS | - |
dc.subject.keywordPlus | COLLECTOR | - |
dc.subject.keywordPlus | DESIGN | - |
dc.relation.journalResearchArea | Thermodynamics | - |
dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.