Indoor Air Quality Sensor Utilization for Unwanted Fire Alarm Improvement in Studio-Type Apartments
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Han-bit | - |
dc.contributor.author | Hwang, Euy-hong | - |
dc.contributor.author | Choi, Don-mook | - |
dc.date.accessioned | 2023-08-20T19:41:12Z | - |
dc.date.available | 2023-08-20T19:41:12Z | - |
dc.date.created | 2023-08-20 | - |
dc.date.issued | 2023-07 | - |
dc.identifier.issn | 2571-6255 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/88809 | - |
dc.description.abstract | Smoke detectors play a vital role in evacuation and safety during fire incidents, as they directly contribute to the reliability and accuracy of firefighting systems. However, if not installed properly, smoke detectors can trigger unwanted fire alarms (UWFAs), particularly in studio-type apartments. Therefore, this study aimed to develop a method for reducing UWFAs by addressing the challenges posed by cooking by-products in such environments. The proposed algorithm was validated through tests, considering relevant literature and standards, and utilizing indoor air quality sensors. Verification tests were conducted to enhance the accuracy of the algorithm. Based on the experimental results, cutoff values of 5 ppm for CO and 7000 & mu;g/m(3) for PM10.0 were proposed as criteria for identifying UWFAs caused by cooking by-products. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.relation.isPartOf | FIRE-SWITZERLAND | - |
dc.title | Indoor Air Quality Sensor Utilization for Unwanted Fire Alarm Improvement in Studio-Type Apartments | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 001036217900001 | - |
dc.identifier.doi | 10.3390/fire6070255 | - |
dc.identifier.bibliographicCitation | FIRE-SWITZERLAND, v.6, no.7 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.scopusid | 2-s2.0-85166202289 | - |
dc.citation.title | FIRE-SWITZERLAND | - |
dc.citation.volume | 6 | - |
dc.citation.number | 7 | - |
dc.contributor.affiliatedAuthor | Choi, Han-bit | - |
dc.contributor.affiliatedAuthor | Hwang, Euy-hong | - |
dc.contributor.affiliatedAuthor | Choi, Don-mook | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | unwanted fire alarm | - |
dc.subject.keywordAuthor | studio-type apartment | - |
dc.subject.keywordAuthor | cooking nuisance | - |
dc.subject.keywordAuthor | indoor air quality sensor | - |
dc.subject.keywordAuthor | thin-sliced pork belly | - |
dc.subject.keywordAuthor | mackerel | - |
dc.subject.keywordAuthor | smoke detector | - |
dc.subject.keywordAuthor | carbon monoxide | - |
dc.subject.keywordAuthor | particulate matter | - |
dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
dc.relation.journalResearchArea | Forestry | - |
dc.relation.journalWebOfScienceCategory | Ecology | - |
dc.relation.journalWebOfScienceCategory | Forestry | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.