Preventing overloaded dissemination in healthcare applications using NonDelay tolerant dissemination technique
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Anjum, Mohd | - |
dc.contributor.author | Shahab, Sana | - |
dc.contributor.author | Whangbo, Taegkeun | - |
dc.contributor.author | Ahmad, Shabir | - |
dc.date.accessioned | 2023-09-15T15:40:59Z | - |
dc.date.available | 2023-09-15T15:40:59Z | - |
dc.date.created | 2023-09-15 | - |
dc.date.issued | 2023-08 | - |
dc.identifier.issn | 2405-8440 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/89103 | - |
dc.description.abstract | Wearable Sensors (WSs) are widely used in healthcare applications to monitor patient health. During the data transmission, dissemination requires additional time to transmit the details with minimum computation difficulties. The existing techniques consume high overloaded while transmitting data in healthcare applications. The research problem is overcome by applying the non-delay-tolerant dissemination technique (NDTDT) to prevent overloaded dissemination and augment immediate, swift message delivery. The dissemination techniques utilize the intelligent decision-making process to provide the accumulated details to the healthcare center. The pro-posed approach is reliable in mitigating the errors due to inconsistent and discrete sensing in-tervals between the WSs. The constraints due to delay and interrupted transmission losses are reduced by selecting appropriate slots for WS information handling. This technique aims at maximizing the delivery of accumulated WS information through non-submissive or underlay dissemination. The method is designed to reduce dissemination delay and maximize successful message delivery. Two variations, sensors and data flows, validate the proposed NDTDT system's performance. The model increases the delivery rate by 0.91% and 0.932%, the dissemination probability by 0.964% and 0.98%, and the final metrics involved are an average delay of 12.78 ms and 11.67 ms. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | CELL PRESS | - |
dc.relation.isPartOf | HELIYON | - |
dc.title | Preventing overloaded dissemination in healthcare applications using NonDelay tolerant dissemination technique | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 001052348800001 | - |
dc.identifier.doi | 10.1016/j.heliyon.2023.e18783 | - |
dc.identifier.bibliographicCitation | HELIYON, v.9, no.8 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.scopusid | 2-s2.0-85166333068 | - |
dc.citation.title | HELIYON | - |
dc.citation.volume | 9 | - |
dc.citation.number | 8 | - |
dc.contributor.affiliatedAuthor | Whangbo, Taegkeun | - |
dc.contributor.affiliatedAuthor | Ahmad, Shabir | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | Data dissemination | - |
dc.subject.keywordAuthor | Healthcare applications | - |
dc.subject.keywordAuthor | Non-delay tolerant | - |
dc.subject.keywordAuthor | Wearable sensors | - |
dc.subject.keywordPlus | WEARABLE SENSORS | - |
dc.subject.keywordPlus | TRANSMISSION | - |
dc.subject.keywordPlus | MECHANISM | - |
dc.subject.keywordPlus | FRAMEWORK | - |
dc.subject.keywordPlus | DEVICES | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.