Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electrochemical Monitoring of Sulfadiazine via La@CeO Incorporated with Reduced Graphene Oxide

Full metadata record
DC Field Value Language
dc.contributor.authorDisouza, F.P.D.-
dc.contributor.authorSundaresan, R.-
dc.contributor.authorChen, S.-M.-
dc.contributor.authorRamachandran, B.-
dc.contributor.authorChandrasekar, N.-
dc.date.accessioned2023-10-18T01:40:22Z-
dc.date.available2023-10-18T01:40:22Z-
dc.date.issued2023-09-
dc.identifier.issn2673-4532-
dc.identifier.issn2673-4532-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/89362-
dc.description.abstractIn recent years, indiscriminate consumption and dumping of antibiotics have become destructive to human health and causes ecotoxicological pollution. Here, the irregular particle nanosized dendrite structure of lanthanum-doped cerium oxide (LCO) decorated with sheet-like reduced graphene oxide (RGO) composite was utilized to detect the sulfonamide-based drug sulfadiazine (SZ). LCO@RGO nanocomposite was prepared using the hydrothermal method, the synergistic effect between LCO and RGO facilitates electron transferability and conductivity which enhances the electrochemical properties toward the detection of SZ. The detection of SZ expressed a lower detection limit (0.005 µM) and linear range (0.01–265 µM) of the fabricated LCO@RGO/GCE electrode toward SZ, analyzed using the highly sensitive DPV technique. Also, DPV was utilized to determined shows good repeatability, reproducibility, and storage stability of fabricated LCO@RGO/GCE. Moreover, effective practicability was proven in human blood serum and river water samples with great recovery results. All the above probes the synthesized LCO@RGO’s thriving and outstanding electrocatalytic performance of this nanocomposite’s highly sensitive detection of SZ in real biological and environmental samples. © 2023 by the authors.-
dc.format.extent13-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleElectrochemical Monitoring of Sulfadiazine via La@CeO Incorporated with Reduced Graphene Oxide-
dc.typeArticle-
dc.identifier.wosid001199225400001-
dc.identifier.doi10.3390/analytica4030023-
dc.identifier.bibliographicCitationAnalytica, v.4, no.3, pp 300 - 312-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85173468192-
dc.citation.endPage312-
dc.citation.startPage300-
dc.citation.titleAnalytica-
dc.citation.volume4-
dc.citation.number3-
dc.type.docTypeArticle-
dc.publisher.location스위스-
dc.subject.keywordAuthordifferential pulse voltammetry-
dc.subject.keywordAuthorhydrothermal-
dc.subject.keywordAuthorreduced graphene oxide-
dc.subject.keywordAuthorsulfonamides-
dc.subject.keywordPlusVOLTAMMETRIC DETERMINATION-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusNANOPARTICLES-
dc.subject.keywordPlusELECTRODE-
dc.subject.keywordPlusVALIDATION-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.description.journalRegisteredClassforeign-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE