DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cha, Bo Kyung | - |
dc.contributor.author | Lee, Youngjin | - |
dc.contributor.author | Kim, Kyuseok | - |
dc.date.accessioned | 2023-12-15T15:09:37Z | - |
dc.date.available | 2023-12-15T15:09:37Z | - |
dc.date.issued | 2023-10 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.issn | 1424-3210 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/89561 | - |
dc.description.abstract | An indirect conversion X-ray detector uses a scintillator that utilizes the proportionality of the intensity of incident radiation to the amount of visible light emitted. A thicker scintillator reduces the patient's dose while decreasing the sharpness. A thin scintillator has an advantage in terms of sharpness; however, its noise component increases. Thus, the proposed method converts the spatial resolution of radiographic images acquired from a normal-thickness scintillation detector into a thin-thickness scintillation detector. Note that noise amplification and artifacts were minimized as much as possible after non-blind deconvolution. To accomplish this, the proposed algorithm estimates the optimal point-spread function (PSF) when the structural similarity index (SSIM) and feature similarity index (FSIM) are the most similar between thick and thin scintillator images. Simulation and experimental results demonstrate the viability of the proposed method. Moreover, the deconvolution images obtained using the proposed scheme show an effective image restoration method in terms of the human visible system compared to that of the traditional PSF measurement technique. Consequently, the proposed method is useful for restoring degraded images using the adaptive PSF while preventing noise amplification and artifacts and is effective in improving the image quality in the present X-ray imaging system. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | MDPI | - |
dc.title | Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging | - |
dc.type | Article | - |
dc.identifier.wosid | 001097368300001 | - |
dc.identifier.doi | 10.3390/s23198185 | - |
dc.identifier.bibliographicCitation | SENSORS, v.23, no.19 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.scopusid | 2-s2.0-85173987733 | - |
dc.citation.title | SENSORS | - |
dc.citation.volume | 23 | - |
dc.citation.number | 19 | - |
dc.type.docType | Article | - |
dc.publisher.location | 스위스 | - |
dc.subject.keywordAuthor | image restoration | - |
dc.subject.keywordAuthor | non-blind deconvolution | - |
dc.subject.keywordAuthor | image quality assessment | - |
dc.subject.keywordAuthor | scintillator thickness | - |
dc.subject.keywordAuthor | adaptive point-spread function | - |
dc.subject.keywordPlus | TO-NOISE RATIO | - |
dc.subject.keywordPlus | QUALITY CHARACTERIZATION | - |
dc.subject.keywordPlus | COMPUTED RADIOGRAPHY | - |
dc.subject.keywordPlus | DIGITAL RADIOGRAPHY | - |
dc.subject.keywordPlus | SCATTERED RADIATION | - |
dc.subject.keywordPlus | DECONVOLUTION | - |
dc.subject.keywordPlus | RESTORATION | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | MODEL | - |
dc.subject.keywordPlus | PHOTOCONDUCTORS | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.