Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

관심 영역 설정에 따른 Gates법 토리여과율의 유효성 평가

Full metadata record
DC Field Value Language
dc.contributor.author박수영-
dc.contributor.author안성민-
dc.date.accessioned2023-12-26T01:00:22Z-
dc.date.available2023-12-26T01:00:22Z-
dc.date.issued2023-10-
dc.identifier.issn2288-3509-
dc.identifier.issn2384-1168-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/89798-
dc.description.abstractThe glomerular filtration rate (GFR) has been the subject of much research as a key indicator for diagnosing, treating, and monitoring kidney function. The gamma camera method (Gates method) is simple and allows simultaneous acquisition of GFR and renal scintigraphy for each kidney, however its accuracy is inferior. This study aimed to investigate changes in GFR depending on how region of interest (ROI) are set up, which is one of many factors influencing accuracy. GFR was calculated by setting the ROI for each phase of the image acquisition time (Gates-1: 0∼1 minutes, Gates-2: 1∼3 minutes, Gates-3: 3∼27 minutes), and statistical significance was verified based on probability value 0.05 through ANOVA analysis. While there was no statistically significant difference among results from Gates-1, 2, 3 (p=0.481>0.05), overall results from the Gates method tended to overestimate compared to those from the multiple blood sampling-dual exponential (MBSDE) method. When comparing averages between phases, results from Gates-2 were most similar to those from the MBSDE method. Moreover, paired t-test p-values between MBSDE method and phases were as follows Gates-1: 0.021 (p<0.05), Gates-2: 0.280 (p>0.05), and Gates-3: 0.164 (p>0.05) indicating that only Gates-1 had statistically significant differences compared with MBSDE method. Thus, setting ROI around 2∼3 minutes is calculated can aid in accurately determining GFR when Gates Method.-
dc.format.extent9-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한방사선과학회-
dc.title관심 영역 설정에 따른 Gates법 토리여과율의 유효성 평가-
dc.title.alternativeEvaluation of Validity Glomerular Filtration Rate Measured by Gates Method according Region of Interest-
dc.typeArticle-
dc.identifier.bibliographicCitation방사선기술과학, v.46, no.5, pp 417 - 425-
dc.identifier.kciidART003011284-
dc.description.isOpenAccessN-
dc.citation.endPage425-
dc.citation.startPage417-
dc.citation.title방사선기술과학-
dc.citation.volume46-
dc.citation.number5-
dc.publisher.location대한민국-
dc.subject.keywordAuthor토리여과율-
dc.subject.keywordAuthor다중채혈 이중 지수 법-
dc.subject.keywordAuthor감마카메라-
dc.subject.keywordAuthorGates 법-
dc.subject.keywordAuthor관심 영역-
dc.subject.keywordAuthorGlomerular Filtration Rate (GFR)-
dc.subject.keywordAuthorMultiple Blood Sampling-Dual Exponential Method (MBSDE)-
dc.subject.keywordAuthorGamma Camera-
dc.subject.keywordAuthorGates Method-
dc.subject.keywordAuthorRegion Of Interest (ROI)-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Sung Min photo

Ahn, Sung Min
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE