Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

간 초음파 영상에서의 스페클 노이즈 제거를 위한 필터들의 비교 평가

Full metadata record
DC Field Value Language
dc.contributor.author김하진-
dc.contributor.author이영진-
dc.date.accessioned2024-01-02T08:00:14Z-
dc.date.available2024-01-02T08:00:14Z-
dc.date.issued2023-12-
dc.identifier.issn2288-3509-
dc.identifier.issn2384-1168-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/89903-
dc.description.abstractThis study aimed to compare filters for reducing speckle noise in ultrasound images using clinical liver images. We acquired the clinical liver ultrasound images, and noisy images were obtained by adding 0.01, 0.05, 0.10, and 0.50 intensity levels of speckle noise to the liver images. The Wiener filter, median modified Wiener filter, gamma filter, and Lee filter were designed for the noisy images by setting window sizes at 3×3, 5×5, and 7×7. The coefficient of variation (COV) and contrast to noise ratio (CNR) were calculated to evaluate noise reduction and various filters. Moreover, the fil- ter with the highest image quality was selected and quantitatively compared to a noisy image. As a result, COV and CNR showed the noise improved result when the Lee filter was applied. Furthermore, the Lee filter image with a window size of 7×7 was noted to possess approximately a minimum of 1.28 to a maximum of 3.38 times better COV and a minimum of 2.18 to a maximum of 5.50 times better CNR than the noisy image. In conclusion, we confirmed that the Lee filter was effective in reducing speckle noise and proved that an appropriate window size needs to be set considering blurring.-
dc.format.extent10-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한방사선과학회-
dc.title간 초음파 영상에서의 스페클 노이즈 제거를 위한 필터들의 비교 평가-
dc.title.alternativeComparative Evaluation of Filters for Speckle Noise Reduction in a Clinical Liver Ultrasound Image-
dc.typeArticle-
dc.identifier.bibliographicCitation방사선기술과학, v.46, no.6, pp 475 - 484-
dc.identifier.kciidART003034596-
dc.description.isOpenAccessN-
dc.citation.endPage484-
dc.citation.startPage475-
dc.citation.title방사선기술과학-
dc.citation.volume46-
dc.citation.number6-
dc.publisher.location대한민국-
dc.subject.keywordAuthor간 초음파 영상-
dc.subject.keywordAuthor간 혈관-
dc.subject.keywordAuthor스페클 노이즈 제거-
dc.subject.keywordAuthorLee 필터-
dc.subject.keywordAuthor윈도우 크기-
dc.subject.keywordAuthor정량적 평가-
dc.subject.keywordAuthorLiver Ultrasound Image-
dc.subject.keywordAuthorLiver Blood Vessel-
dc.subject.keywordAuthorSpeckle Noise Reduction-
dc.subject.keywordAuthorLee Filter-
dc.subject.keywordAuthorWindow Size-
dc.subject.keywordAuthorQuantitative Evaluation-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE