Synthesis, structural characterization and anticorrosion properties of a new hexafunctional epoxy prepolymer based on urea and phosphorus trichloride for E24 carbon steel in 1.0 M HCl
- Authors
- El-Aouni, Naoual; Dagdag, Omar; El Amri, Abdeslam; Kim, Hansang; Haldhar, Rajesh; Kim, Seong-Cheol; Dkhireche, Nadia; El Bachiri, Abderrahim; Berisha, Avni; Rafik, Mohamed
- Issue Date
- Feb-2024
- Publisher
- ELSEVIER
- Keywords
- Hexafunctional epoxy resin; HGATUP; Microscopic characterizations; Inhibition; Viscosity; Electrochemical methods and theoretical methods
- Citation
- COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, v.682
- Journal Title
- COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS
- Volume
- 682
- URI
- https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/90427
- DOI
- 10.1016/j.colsurfa.2023.132963
- ISSN
- 0927-7757
1873-4359
- Abstract
- Our goal is to set up a synthetic method to produce the hexaglycidyl amine tri-urea phosphoric acid (HGATUP), a novel hexafunctional prepolymer. We created this prepolymer by phosphorylating urea in two processes. Next, to generate the new prepolymer, we added epichlorohydrin. In addition, we focused on its microscopic characterization using FTIR and NMR. The novel HGATUP prepolymer was utilized as a corrosion inhibitor for E24 carbon steel in a 1.0 M hydrochloric acid (HCl) solution. PDP, EIS, EFM, DFT, Monte Carlo (MC), and molecular dynamic (MD) simulations were used in this study. SEM/EDS and XPS studies were also used to investigate the surface morphology. These methods allowed us to examine the sample's surface characteristics and chemical composition, which added to our understanding of the adsorption along with corrosion prevention processes. The electrochemical tests' outcomes also showed that the concentration of HGATUP enhanced inhibitory performance. PDP results indicated that HGATUP at a concentration of 10-3 M had a corrosion inhibition efficiency of 97.6% at 298 K ambient temperature. The polarization curve confirmed that the HGATUP was a mixed type of inhibitor that could inhibit steel anodic and cathodic reactions. The Langmuir model predicted that an epoxy prepolymer protected the surface of E24 carbon steel. Calculated thermodynamic kinetic parameters were used to analyze the inhibitor adsorption processes.surface morphology. These methods allowed us to examine the sample's surface characteristics and chemical composition, which added to our understanding of the adsorption along with corrosion prevention processes. The electrochemical tests' outcomes also showed that the concentration of HGATUP enhanced inhibitory performance. PDP results indicated that HGATUP at a concentration of 10-3 M had a corrosion inhibition efficiency of 97.6% at 298 K ambient temperature. The polarization curve confirmed that the HGATUP was a mixed type of inhibitor that could inhibit steel anodic and cathodic reactions. The Langmuir model predicted that an epoxy prepolymer protected the surface of E24 carbon steel. Calculated thermodynamic kinetic parameters were used to analyze the inhibitor adsorption processes.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - ETC > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.