Development of an Artificial Soft Solid Gel Using Gelatin Material for High-Quality Ultrasound Diagnosis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Minchan | - |
dc.contributor.author | Yoon, Kicheol | - |
dc.contributor.author | Lee, Sangyun | - |
dc.contributor.author | Shin, Mi-Seung | - |
dc.contributor.author | Kim, Kwang Gi | - |
dc.date.accessioned | 2024-03-11T12:00:26Z | - |
dc.date.available | 2024-03-11T12:00:26Z | - |
dc.date.issued | 2024-02 | - |
dc.identifier.issn | 2075-4418 | - |
dc.identifier.issn | 2075-4418 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/90635 | - |
dc.description.abstract | For ultrasound diagnosis, a gel is applied to the skin. Ultrasound gel serves to block air exposure and match impedance between the skin and the probe, enhancing imaging efficiency. However, if use of the ultrasound gel exceeds a certain period of time, it may dry out and be exposed to air, causing impedance mismatch and reducing imaging resolution. In such cases, the use of a soft, solid gel proves advantageous, as it can be employed for an extended period without succumbing to the drying phenomenon and can be reused after disinfection. Its soft consistency ensures excellent skin adhesion. Our soft solid gel demonstrated approximately 1.2 times better performance than water, silicone, and traditional ultrasound gels. When comparing the dimensions of grayscale, dead zone, vertical, and horizontal regions, the measurements for the traditional ultrasound gel were 93.79 mm, 45.32 mm, 103.13 mm, 83.86 mm, and 83.86 mm, respectively. In contrast, the proposed soft solid gel exhibited dimensions of 105.64 mm, 34.48 mm, 141.1 mm, and 102.8 mm. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | MDPI | - |
dc.title | Development of an Artificial Soft Solid Gel Using Gelatin Material for High-Quality Ultrasound Diagnosis | - |
dc.type | Article | - |
dc.identifier.wosid | 001160194000001 | - |
dc.identifier.doi | 10.3390/diagnostics14030335 | - |
dc.identifier.bibliographicCitation | DIAGNOSTICS, v.14, no.3 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.scopusid | 2-s2.0-85184727936 | - |
dc.citation.title | DIAGNOSTICS | - |
dc.citation.volume | 14 | - |
dc.citation.number | 3 | - |
dc.type.docType | Article | - |
dc.publisher.location | 스위스 | - |
dc.subject.keywordAuthor | ultrasound test soft solid gel (ATS-539) | - |
dc.subject.keywordAuthor | ultrasound gel | - |
dc.subject.keywordAuthor | gelatin powder | - |
dc.subject.keywordAuthor | sector probe | - |
dc.subject.keywordAuthor | monitoring | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.