Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Artificial Tear Instillation-Induced Changes in Corneal Topography

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Yunjin-
dc.contributor.authorKim, Tae Hun-
dc.contributor.authorPaik, Hae Jung-
dc.contributor.authorKim, Dong Hyun-
dc.date.accessioned2024-04-02T13:30:24Z-
dc.date.available2024-04-02T13:30:24Z-
dc.date.issued2024-02-
dc.identifier.issn2306-5354-
dc.identifier.issn2306-5354-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/90866-
dc.description.abstractThis study aims to compare changes of corneal topography (Galilei G4) before and after the instillation of artificial tears in patients with dry eye disease (DED). Corneal topography was performed in patients 1 min before and after artificial tear instillation. Two types of artificial tears were used: 1% polysorbate 80 (PSB) and 0.5% carboxymethylcellulose (CMC). Of 135 patients, PSB and CMC were instilled in 101 and 34 eyes, respectively. The average value of Sim K increased significantly after instillation (44.07 +/- 2.26 diopter (D)) compared to before (43.90 +/- 2.02 D, p = 0.006) the instillation of artificial tears. Mean Sim K astigmatism was statistically increased after PSB instillation (1.48 +/- 2.17 D) compared to before instillation (1.31 +/- 2.10 D, p = 0.049). An axis change of astigmatism 10 degrees or more after artificial tear instillation was found in 51.9% of patients, and 30 degrees or more in 20.0% of patients. Increased Sim K value and significant changes in the astigmatic axis in the corneal topography were observed after instillation of artificial tears in DED patients. PSB instillation had a greater effect on corneal keratometry values than CMC instillation.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleArtificial Tear Instillation-Induced Changes in Corneal Topography-
dc.typeArticle-
dc.identifier.wosid001172083300001-
dc.identifier.doi10.3390/bioengineering11020121-
dc.identifier.bibliographicCitationBIOENGINEERING-BASEL, v.11, no.2-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85185906372-
dc.citation.titleBIOENGINEERING-BASEL-
dc.citation.volume11-
dc.citation.number2-
dc.type.docTypeArticle-
dc.publisher.location스위스-
dc.subject.keywordAuthorcorneal topography-
dc.subject.keywordAuthorkeratometry-
dc.subject.keywordAuthorastigmatism-
dc.subject.keywordAuthorartificial tear-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Yunjin photo

Lee, Yunjin
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE