Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Optimization of Automated Suspension Trapping Digestion in Bottom-Up Proteomics via Mass Spectrometry

Full metadata record
DC Field Value Language
dc.contributor.authorSong, Haneul-
dc.contributor.authorJeon, Yejin-
dc.contributor.authorChoi, Iyun-
dc.contributor.authorJoo, Minjoong-
dc.contributor.authorPark, Jong-Moon-
dc.contributor.authorLee, Hookeun-
dc.date.accessioned2024-05-01T11:00:19Z-
dc.date.available2024-05-01T11:00:19Z-
dc.date.issued2024-03-
dc.identifier.issn2233-4203-
dc.identifier.issn2093-8950-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/91073-
dc.description.abstractThe Suspension Trapping (S-Trap) method has been a prominent sample preparation technique since its introduction in 2014. Its capacity to induce protein aggregation using organic solvents has significantly improved protein purification and facilitated peptide identification. However, its full potential for automation has been limited by the lack of a suitable liquid handling system until recently. In this study, we aimed to enhance the automation of S-Trap sample preparation by optimizing the S-Trap digestion process, incorporating triethylammonium bicarbonate (TEAB) and CaCl2. The utilization of TEAB buffer conditions in this innovative process led to a noteworthy 12% improvement in protein identification. Additionally, through careful observation of various incubation conditions, we streamlined the entire sample preparation workflow into a concise 4 hours timeline, covering reduction, alkylation, and trypsin incubation stages. This refined and expedited automated S-Trap digestion process not only showcased exceptional time efficiency but also improved trypsin digestion, resulting in increased protein identification. © Korean Society for Mass Spectrometry.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherKorean Society for Mass Spectrometry-
dc.titleOptimization of Automated Suspension Trapping Digestion in Bottom-Up Proteomics via Mass Spectrometry-
dc.typeArticle-
dc.identifier.wosid001246210000006-
dc.identifier.doi10.5478/MSL.2024.15.1.62-
dc.identifier.bibliographicCitationMass Spectrometry Letters, v.15, no.1, pp 62 - 68-
dc.identifier.kciidART003068427-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85191173788-
dc.citation.endPage68-
dc.citation.startPage62-
dc.citation.titleMass Spectrometry Letters-
dc.citation.volume15-
dc.citation.number1-
dc.type.docTypeArticle-
dc.publisher.location대한민국-
dc.subject.keywordAuthorAutomated Sample Preparation-
dc.subject.keywordAuthorMass Spectrometry-
dc.subject.keywordAuthorSuspension Trapping (S-Trap)-
dc.relation.journalResearchAreaSpectroscopy-
dc.relation.journalWebOfScienceCategorySpectroscopy-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClassesci-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Hoo Keun photo

Lee, Hoo Keun
Pharmacy (Dept.of Pharmacy)
Read more

Altmetrics

Total Views & Downloads

BROWSE