Optimization of search window and mask size for non-local means noise reduction algorithm in chest digital tomosynthesis: a phantom study

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Kyuseok-
dc.contributor.authorPark, Minji-
dc.contributor.authorLim, Sewon-
dc.contributor.authorKim, Hajin-
dc.contributor.authorKang, Seong-Hyeon-
dc.contributor.authorJeong, Hyun-Woo-
dc.contributor.authorLee, Youngjin-
dc.date.accessioned2024-06-06T09:00:17Z-
dc.date.available2024-06-06T09:00:17Z-
dc.date.issued2024-04-
dc.identifier.issn0374-4884-
dc.identifier.issn1976-8524-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/91451-
dc.description.abstractAmong the parameters of non-local means (NLM) noise reduction algorithm, the search window and mask size have a great influence on the quality of diagnostic medical images. In this study, we aim to optimize the NLM noise reduction algorithm in the chest digital tomosynthesis (CDT) system. The parameters of the NLM algorithm were set to a search window of 11 x 11 to 101 x 101 and a mask size of 3 x 3 to 11 x 11. The quantitative evaluation method of the acquired CDT image used coefficient of variation (COV) and contrast-to-noise ratio (CNR). COV showed improved results as the search window was increased, and CNR showed the best results at a window size of 61 x 61. In addition, we could confirm that the COV and CNR steadily improved as the size of the mask increased. In conclusion, we expect that when applying the NLM noise reduction algorithm to CDT X-ray images, appropriate parameters can be derived and applied.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN PHYSICAL SOC-
dc.titleOptimization of search window and mask size for non-local means noise reduction algorithm in chest digital tomosynthesis: a phantom study-
dc.typeArticle-
dc.identifier.wosid001174683800001-
dc.identifier.doi10.1007/s40042-024-01007-9-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.84, no.7, pp 566 - 572-
dc.identifier.kciidART003071267-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85186579122-
dc.citation.endPage572-
dc.citation.startPage566-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume84-
dc.citation.number7-
dc.type.docTypeArticle-
dc.publisher.location대한민국-
dc.subject.keywordAuthorNon-local means (NLM) approach-
dc.subject.keywordAuthorNoise reduction algorithm-
dc.subject.keywordAuthorOptimization for algorithm-
dc.subject.keywordAuthorChest digital tomosynthesis (CDT)-
dc.subject.keywordAuthorQuantitative evaluation of image quality-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads