Optimization of search window and mask size for non-local means noise reduction algorithm in chest digital tomosynthesis: a phantom study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Kyuseok | - |
dc.contributor.author | Park, Minji | - |
dc.contributor.author | Lim, Sewon | - |
dc.contributor.author | Kim, Hajin | - |
dc.contributor.author | Kang, Seong-Hyeon | - |
dc.contributor.author | Jeong, Hyun-Woo | - |
dc.contributor.author | Lee, Youngjin | - |
dc.date.accessioned | 2024-06-06T09:00:17Z | - |
dc.date.available | 2024-06-06T09:00:17Z | - |
dc.date.issued | 2024-04 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.issn | 1976-8524 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/91451 | - |
dc.description.abstract | Among the parameters of non-local means (NLM) noise reduction algorithm, the search window and mask size have a great influence on the quality of diagnostic medical images. In this study, we aim to optimize the NLM noise reduction algorithm in the chest digital tomosynthesis (CDT) system. The parameters of the NLM algorithm were set to a search window of 11 x 11 to 101 x 101 and a mask size of 3 x 3 to 11 x 11. The quantitative evaluation method of the acquired CDT image used coefficient of variation (COV) and contrast-to-noise ratio (CNR). COV showed improved results as the search window was increased, and CNR showed the best results at a window size of 61 x 61. In addition, we could confirm that the COV and CNR steadily improved as the size of the mask increased. In conclusion, we expect that when applying the NLM noise reduction algorithm to CDT X-ray images, appropriate parameters can be derived and applied. | - |
dc.format.extent | 7 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.title | Optimization of search window and mask size for non-local means noise reduction algorithm in chest digital tomosynthesis: a phantom study | - |
dc.type | Article | - |
dc.identifier.wosid | 001174683800001 | - |
dc.identifier.doi | 10.1007/s40042-024-01007-9 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.84, no.7, pp 566 - 572 | - |
dc.identifier.kciid | ART003071267 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-85186579122 | - |
dc.citation.endPage | 572 | - |
dc.citation.startPage | 566 | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 84 | - |
dc.citation.number | 7 | - |
dc.type.docType | Article | - |
dc.publisher.location | 대한민국 | - |
dc.subject.keywordAuthor | Non-local means (NLM) approach | - |
dc.subject.keywordAuthor | Noise reduction algorithm | - |
dc.subject.keywordAuthor | Optimization for algorithm | - |
dc.subject.keywordAuthor | Chest digital tomosynthesis (CDT) | - |
dc.subject.keywordAuthor | Quantitative evaluation of image quality | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.